Round-Robin Tests with Relocatable Coverslips Improve Asbestos Fibre Counting

Abstract: Asbestos fibre counting by phase-contrast microscope is subject to many sources of variation, including those dependent on the analyst. In this study, asbestos sample slides prepared with relocatable coverslips have been used for fibre counting among voluntary analysts to evaluate their proficiency. One slide of amosite and one of chrysotile were distributed to all the analysts, and three proficiency testing rounds were conducted for amosite and four for chrysotile. Each relocatable coverslip has a report in w… Show more