Abstract:We experimentally determined the pressure limits that can be used to autoclavebond RTNS-II targets without crushing the internal cooling channels. The maximum pressures are 40 to 55 MPa (6 to 8 ksi) in trv? 300-to-450°C temperature regime.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.