2010
DOI: 10.1136/thx.2010.150953.11
|View full text |Cite
|
Sign up to set email alerts
|

S160 The effect of shift work on serial peak expiratory flow measurements used to diagnose occupational asthma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0
8

Year Published

2012
2012
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(35 citation statements)
references
References 0 publications
1
26
0
8
Order By: Relevance
“…3) The sensitivity and specificity of serial peak flow measurements is high in the diagnosis of work-related asthma (***) [48].…”
Section: Strength Of Evidence and Grading Of Recommendationmentioning
confidence: 99%
See 2 more Smart Citations
“…3) The sensitivity and specificity of serial peak flow measurements is high in the diagnosis of work-related asthma (***) [48].…”
Section: Strength Of Evidence and Grading Of Recommendationmentioning
confidence: 99%
“…The evidence for serial measurements of peak expiratory flow (PEF) is taken from an evidence-based review [48] and is compatible with the AHRQ meta-analysis.…”
Section: Commentsmentioning
confidence: 99%
See 1 more Smart Citation
“…5). When serial PEFs are of good quality, the mean pooled sensitivity for the diagnosis of occupational asthma is 82% and specificity is 89% [13]. FEV1 is the main measure used in specialised testing, such as specific inhalation challenge tests for the diagnosis of occupational asthma.…”
Section: Spirometry In the Workplacementioning
confidence: 99%
“…The diagnosis of asthma was based on the history of asthmatic symptoms and positive metacholine challenge test [11]. The workrelatedness of asthma was evaluated by serial peak expiratory flow rate (PEFR) measurements according to the actual recommendations [12,13]. The diagnosis of OA (sensitizer-induced OA) was established by finding of significant changes of the PEFR values registered in the periods at and away from work [14].…”
Section: Diagnostic Work-upmentioning
confidence: 99%