2000
DOI: 10.1039/b000861n
|View full text |Cite
|
Sign up to set email alerts
|

Salbutamol plastic membrane electrodes based on individual and mixed ion-exchangers of salbutamolium phosphotungstate and phosphomolybdate

Abstract: Salbutamol (Sl), also known as albuterol, selective PVC membranes based on ion associates of salbutamolium phosphotungstate (Sl-PTA), salbutamolium phosphomolybdate (Sl-PMA) or a mixture of both (Sl-PTA/PMA) were prepared. The electrodes displayed a linear response over the concentration range 6.3 3 10 26 -1.0 3 10 21 mol dm 23 salbutamol sulfate (Sl 2 SO 4 ). The working pH ranges of the above electrodes were 2.5-11.0, 3.0-11.0 and 2.5-10.5 and their isothermal temperature coefficients were 0.00095, 0.00105 a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 34 publications
(9 citation statements)
references
References 23 publications
0
9
0
Order By: Relevance
“…The conventional-type electrodes were constructed as previously described [ 9 ]. The membrane composition was studied by varying the percentages (w/w) of the ion exchanger(s), PVC, and DOP until optimum composition that exhibits the best performance characteristics, and Nernestian behavior is reached.…”
Section: Methodsmentioning
confidence: 99%
“…The conventional-type electrodes were constructed as previously described [ 9 ]. The membrane composition was studied by varying the percentages (w/w) of the ion exchanger(s), PVC, and DOP until optimum composition that exhibits the best performance characteristics, and Nernestian behavior is reached.…”
Section: Methodsmentioning
confidence: 99%
“…For many years, the method of determination of degree of interference by means of selectivity coefficients of electrodes in potentiometric measurements was a subject of discussion in the literature [20]. Two specialized IUPAC committees were convened with regard to the measurements of potentiometric selectivity coefficients.…”
Section: Selectivity Measurementsmentioning
confidence: 99%
“…The conventional electrodes were constructed as described previously [21,22]. The membrane composition was selected by varying the percentage content (w/w) of the ion exchanger, PVC and DOP until optimum conditions were reached.…”
Section: Preparation Of Electrodesmentioning
confidence: 99%