Sampling Trade-Offs in Duty-Cycled Systems for Air Quality Low-Cost Sensors

Abstract: The use of low-cost sensors in conjunction with high-precision instrumentation for air pollution monitoring has shown promising results in recent years. One of the main challenges for these sensors has been the quality of their data, which is why the main efforts have focused on calibrating the sensors using machine learning techniques to improve the data quality. However, there is one aspect that has been overlooked, that is, these sensors are mounted on nodes that may have energy consumption restrictions if … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

3
2

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 34 publications
0
6
0
Order By: Relevance
“…In this line, and as an example of use of this data set, Ferrer-Cid et al. [5] have studied the trade-offs present between the sensor sampling frequency, the quality of the resulting sensor calibration, and the energy consumption of a sensing subsystem. Basically, it is shown how with a larger sampling period a good data quality can be obtained in exchange for significant energy savings.…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this line, and as an example of use of this data set, Ferrer-Cid et al. [5] have studied the trade-offs present between the sensor sampling frequency, the quality of the resulting sensor calibration, and the energy consumption of a sensing subsystem. Basically, it is shown how with a larger sampling period a good data quality can be obtained in exchange for significant energy savings.…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
“…The temperature and relative humidity sensors give readings in C and % respectively. Data source location Institution: Universitat Politécnica de Catalunya (UPC) City/Town/Region: Barcelona Country: Spain GPS coordinates for collected samples/data: Palau Reial Reference Station, Latitude 41.3872889, Longitude 2.115666667 Data accessibility Repository name: Zenodo Files names: 20001_O3_NO2_raw.csv, 20002_O3_NO2_raw.csv, 20001_NO_raw.csv, 20001_T_RH_raw.csv, 20002_T_RH_raw.csv URL: https://doi.org/10.5281/zenodo.5770589 [4] Related research article P. Ferrer-Cid, J. Garcia-Calvete, A. Main-Nadal, Z. Ye, J. M. Barcelo-Ordinas, J. Garcia-Vidal, Sampling trade-offs in duty-cycled systems for air quality low-cost sensors, Sensors 22 (2022) https://doi.org/10.3390/s22103964 [5] . …”
mentioning
confidence: 99%
“…Finally, we define two other data sets called D. In all data sets, the samples are hourly (T =1 h) and are taken with the same aggregation strategy as the reference stations; minute samples are taken and aggregated into hourly samples [30]. In order to have daily 24-hour samples, in case of data loss, e.g.…”
Section: Data Setsmentioning
confidence: 99%
“…Clark and Lyons utilized the strategy of the electrochemical detection of oxygen or hydrogen peroxide to measure glucose in biological samples [9]. The ubiquity of impedance is mainly leveraged to realize gas transducers [10]. Optical sensors are passive, i.e., require an external field excitation source to inject some energy into the observation specimen for measurement [11][12][13].…”
Section: Introductionmentioning