Abstract:This article is a review of literature conducted in as systematic manner using the PRISMA statement as a basis for its methodology to answer the following question: How can EtCO2 measuring assist with CPR attempts in SAR Helicopter paramedic practice?’ Results revealed that CO2 coming out of an ET tube indicates that it is in the correct position. An EtCO2 value of <1.33 KPa or an EtCO2 that falls by ≥ 25% of the baseline are the variables most significantly correlated with not achieving ROSC. Diminishing E… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.