2016
DOI: 10.1152/ajpcell.00094.2016
|View full text |Cite
|
Sign up to set email alerts
|

SarcOptiM for ImageJ: high-frequency online sarcomere length computing on stimulated cardiomyocytes

Abstract: Pasqualin C, Gannier F, Yu A, Malécot CO, Bredeloux P, Maupoil V. SarcOptiM for ImageJ: high-frequency online sarcomere length computing on stimulated cardiomyocytes. Am J Physiol Cell Physiol 311: C277-C283, 2016. First published June 22, 2016; doi:10.1152/ajpcell.00094.2016.-Accurate measurement of cardiomyocyte contraction is a critical issue for scientists working on cardiac physiology and physiopathology of diseases implying contraction impairment. Cardiomyocytes contraction can be quantified by measurin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
49
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 45 publications
(49 citation statements)
references
References 12 publications
0
49
0
Order By: Relevance
“…Isolated CMs were paced at 1 Hz. Bright-field images were acquired and then analyzed using SarcOptiM 18 . In violin plots, white circles show the medians, box limits indicate the 25th and 75th percentiles, whiskers extend 1.5 times the interquartile range from the 25th and 75th percentiles, and polygons represent density estimates of data and extend to extreme values.…”
Section: Resultsmentioning
confidence: 99%
“…Isolated CMs were paced at 1 Hz. Bright-field images were acquired and then analyzed using SarcOptiM 18 . In violin plots, white circles show the medians, box limits indicate the 25th and 75th percentiles, whiskers extend 1.5 times the interquartile range from the 25th and 75th percentiles, and polygons represent density estimates of data and extend to extreme values.…”
Section: Resultsmentioning
confidence: 99%
“…In adult cardiomyocytes, sarcomere length measurements were performed using DIC videos recorded at 100 fps by using the ImageJ plugin SarcOptiM. 39 Briefly, a fast Fourier transformation algorithm is used to extract the regular spacing in a line profile plotted along the longitudinal axis of the cell. Adult cardiomyocytes were electrically paced at 1 Hz with Platinum wire bath electrodes by applying 8 ms square voltage pulses with a maximum electric field of 30 V/cm.…”
Section: Methodsmentioning
confidence: 99%
“…Qualitatively, we observed a shift in the peak-to-peak distance of the traces due to mdivi-1 treatment ( Figure 5B). Next, we used a FFT-based method 48 to calculate the average sarcomere length from 12 consecutive sarcomeres per myotube ( Figure 5C). Sarcomere length was calculated as 2.67 ± 0.03, 2.74 ± 0.03, and 2.79 ± 0.03 in the DMSO control, 10 μM mdivi-1, and 25 μM mdivi-1 groups, respectively, with n = 35 myotubes per condition ( Figure 5D).…”
Section: Sarcomeric Length Increases Due To Mdivi-1 Treatmentmentioning