2000
DOI: 10.1109/23.873018
|View full text |Cite
|
Sign up to set email alerts
|

Scatter and cross-talk corrections in simultaneous Tc-99m/I-123 brain SPECT using constrained factor analysis and artificial neural networks

Abstract: Simultaneous imaging of Tc-99m and 1-123 would have a high clinical potential in the assessment ol' brain perfusion (Tc-99m) and neurotransmission (I-123) but is hindered by cross-talk bctwcen the two radionuclides.Monte Carlo simulations of 15 different dual-isotope studies were performed using a digital brain phantom. Several physiologic Tc-99in and 1-1 23 uptakc patterns were rnodelcd in the brain structures. Two methods wcrc considered to correct for cross-talk from both scattercd and unscattered photons: … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 28 publications
(15 citation statements)
references
References 14 publications
0
15
0
Order By: Relevance
“…Template C was created using images obtained in 5 healthy volunteers (mean age 5 58.8 6 16 y) acquired with a triple-head camera. In this center, projections were acquired in 8 energy windows ranging from 79 to 179 keV, corrected for scatter using a validated artificial neural network (27) and reconstructed with an iterative algorithm that modeled attenuation and variable collimator response in the projector/backprojector of an OSEM algorithm (Fig. 1).…”
Section: Creation Of 3 Additional Normalization Templatesmentioning
confidence: 99%
“…Template C was created using images obtained in 5 healthy volunteers (mean age 5 58.8 6 16 y) acquired with a triple-head camera. In this center, projections were acquired in 8 energy windows ranging from 79 to 179 keV, corrected for scatter using a validated artificial neural network (27) and reconstructed with an iterative algorithm that modeled attenuation and variable collimator response in the projector/backprojector of an OSEM algorithm (Fig. 1).…”
Section: Creation Of 3 Additional Normalization Templatesmentioning
confidence: 99%
“…Downscatter effects have been studied extensively in simultaneous Tl-201=Tc-99m cardiac SPECT. 30 [32][33][34] These methods provide an arsenal of methods for modeling object downscatter and collimator interactions and iterative reconstruction based compensation methods.…”
Section: Introductionmentioning
confidence: 99%
“…Some applied compensation methods with three or four windows to estimate the scattered photons [8][9]. Furthermore, spectral factor analysis (SFA) [10] and artificial neural network (ANN) have been used to reduce scatter and cross-talk [11][12][13][14][15].…”
Section: Independent Component Analysis (Ica)mentioning
confidence: 99%