“…Erminy [2], Kunz [3], Jung [4], and Reule [12] used two or more sources which could be isolated by batHes or rotatable mirrors. See items below for more details on these applications.…”
Section: N+n2•mentioning
confidence: 99%
“…A supplementary source, Ss, provides an adjustable 2 In order to adequately describe mat e rials and experimental procedures, it is occasionally necessary to identify commercial products by manufacturer' s name or label. In no instances does such identification imply endorsement by the National Bureau of Standards.…”
Section: N+n2•mentioning
confidence: 99%
“…Linearity-To the series of s teps of irradiance whi c h Rotter described , we should add that describ ed by Erminy [2]. Erminy used three strip filam e nt lamps, as shown in figure 9.…”
Section: Measurement Of Radiant Fluxes To Testmentioning
The methods desc ribed in the lite rature for acc urately meas urin g photocell linea rity are surveyed and assessed. The effect of not meas uring photocell linearity under th e condition s used in the final appa ratu s are cons idered. So me of the conditions necessa ry for accurate assess ment of the non· lin earity under working conditions are specifi ed. The use of the NRC " Photocell Lin earit y Teste r" to meas ure and correct for the nonlinea rity of various receiv ers is desc ribed.
“…Erminy [2], Kunz [3], Jung [4], and Reule [12] used two or more sources which could be isolated by batHes or rotatable mirrors. See items below for more details on these applications.…”
Section: N+n2•mentioning
confidence: 99%
“…A supplementary source, Ss, provides an adjustable 2 In order to adequately describe mat e rials and experimental procedures, it is occasionally necessary to identify commercial products by manufacturer' s name or label. In no instances does such identification imply endorsement by the National Bureau of Standards.…”
Section: N+n2•mentioning
confidence: 99%
“…Linearity-To the series of s teps of irradiance whi c h Rotter described , we should add that describ ed by Erminy [2]. Erminy used three strip filam e nt lamps, as shown in figure 9.…”
Section: Measurement Of Radiant Fluxes To Testmentioning
The methods desc ribed in the lite rature for acc urately meas urin g photocell linea rity are surveyed and assessed. The effect of not meas uring photocell linearity under th e condition s used in the final appa ratu s are cons idered. So me of the conditions necessa ry for accurate assess ment of the non· lin earity under working conditions are specifi ed. The use of the NRC " Photocell Lin earit y Teste r" to meas ure and correct for the nonlinea rity of various receiv ers is desc ribed.
“…Ratios of 2' where n is an integer could be obtained by this device. Erminy of NRS conceived a scheme for obtaining more numerous ratios and also fractional ratios [12] with a device for conjoining beams from three radiant sources. The method was implemented as shown in Wg.…”
apportera un gain appreciable de pr&&ion, en &tendant qu,elle soit a son tour autre mBthode par exemple le comptage des franges d'inter-f6rence d'un laser, m6thode pour laquelle notre inter-
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.