2020
DOI: 10.1007/s00604-020-04404-6
|View full text |Cite
|
Sign up to set email alerts
|

Screen-printed electrodes modified with carbon black and polyelectrolyte films for determination of cancer marker carbohydrate antigen 19-9

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0
7

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(16 citation statements)
references
References 42 publications
0
9
0
7
Order By: Relevance
“…The corresponding calibration equation is ∆I (µA) = 1.58 + 5.39 log C (U•mL −1 ), having the regression coefficient (R 2 ) of 0.9974 and the limit of detection of 0.82 U•mL −1 based on a signal-to-noise ratio of 3 (S/N = 3). To better further evaluate the electrochemical immunosensors, the performance of our Zn-Co-S@G nanocomposite electrochemical immunosensor is compared with that of other electrochemical immunosensors for detecting the biomarker CA19-9, according to previous reports, which was better or comparable to that of the previous reports, as shown in Table 1 [1,6,[26][27][28][29].…”
Section: Resultsmentioning
confidence: 81%
See 1 more Smart Citation
“…The corresponding calibration equation is ∆I (µA) = 1.58 + 5.39 log C (U•mL −1 ), having the regression coefficient (R 2 ) of 0.9974 and the limit of detection of 0.82 U•mL −1 based on a signal-to-noise ratio of 3 (S/N = 3). To better further evaluate the electrochemical immunosensors, the performance of our Zn-Co-S@G nanocomposite electrochemical immunosensor is compared with that of other electrochemical immunosensors for detecting the biomarker CA19-9, according to previous reports, which was better or comparable to that of the previous reports, as shown in Table 1 [1,6,[26][27][28][29].…”
Section: Resultsmentioning
confidence: 81%
“…(b) The linear range of BSA/anti-CA19-9/GA/CHIT/Zn-Co-S@G/GCE in Figure 8a. Polythionine-Au 0.26 6.5-520 [6] Polythionine/sodium dodecyl sulphate 0.45 5-400 [26] AuPt nanocalliandras 0.03 0.05-50 [27] Carbon nanoonions/grphene oxide 0.12 0.3-100 [28] Carbon black/polyelectrolytes 0.07 0.01-40 [29] Zn-Co-S/graphene 0.82 6.3-300 This work…”
Section: Resultsmentioning
confidence: 99%
“…108 As 6 1,0 × 10 −3 mol L -1 em tampão fosfato 0,1 mol L −1 pH 7. Parâmetros dos voltamogramas de pulso diferencial: tempo de modulação = 0,05 s, amplitude de modulação = 0,09 V e incremento de potencial = 0,05 V. Fonte: Adaptada de IBÁÑEZ-REDÍN et al 101 Posteriormente foi realizada a deposição dos filmes de CB-PEI e CB-PAA nas superfícies dos eletrodos de trabalho pré-tratados. Tanto a concentração de CB nos compósitos quanto o tempo de adsorção dos filmes foram otimizados considerando como critérios a obtenção de voltamogramas de pulso diferencial com boa definição e elevado sinal analítico.…”
Section: Deposicão Lbl Dos Filmes De Cb-polieletrólitos Nos Spcesunclassified
“…Experimentos realizados em solução K 3 Fe(CN) 6 /K 4 Fe(CN) 6 1,0×10 −3 mol L −1 em tampão fosfato 0,1 mol L −1 pH 7. Parâmetros: tempo de modulação = 0,05 s, amplitude de modulação = 0,09 V e incremento de potencial = 0,05 V. Fonte: Adaptada de IBÁÑEZ-REDÍN et al 101 Na Figura 2.9 é apresentada uma proposta para o perfil de difusão da sonda redox Fe(CN) 6 3− /Fe(CN) 6 4− através dos filmes de CB-polieletrólito baseado em BARREIRA e colaboradores. 109 Vale ressaltar que a resposta eletroquímica de eletrodos modificados com compósitos CB-polieletrólito depende especificamente do tipo de sonda utilizada e do seu mecanismo de transferência eletrônica.…”
Section: Deposicão Lbl Dos Filmes De Cb-polieletrólitos Nos Spcesunclassified
See 1 more Smart Citation