Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
87
0

Year Published

2008
2008
2011
2011

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 154 publications
(89 citation statements)
references
References 16 publications
2
87
0
Order By: Relevance
“…In addition, the slopes of these plots indicate that the orbitrap resolution will eventually even exceed that of 7, 9.4, and 14.5 T FT-ICR at 1 sec acquisition time at higher m/z values, because of its weaker mass dependence (see Section III.F). Although the measured mass accuracy was worse (compared to <5 ppm for 7.0 T LTQ-FT-ICR and TOF instruments), changes to the injection optics in later instrument designs achieved comparable performance of 2-5 ppm (Hardman & Makarov, 2003;Hu et al, 2005;Makarov et al, 2006a;Nielen et al, 2007). Mass accuracy remains worse than that of magnetic sectors which can routinely achieve 1 ppm accuracies (Bristow, 2006).…”
Section: A Electrostatic Acceleration Lensesmentioning
confidence: 94%
See 3 more Smart Citations
“…In addition, the slopes of these plots indicate that the orbitrap resolution will eventually even exceed that of 7, 9.4, and 14.5 T FT-ICR at 1 sec acquisition time at higher m/z values, because of its weaker mass dependence (see Section III.F). Although the measured mass accuracy was worse (compared to <5 ppm for 7.0 T LTQ-FT-ICR and TOF instruments), changes to the injection optics in later instrument designs achieved comparable performance of 2-5 ppm (Hardman & Makarov, 2003;Hu et al, 2005;Makarov et al, 2006a;Nielen et al, 2007). Mass accuracy remains worse than that of magnetic sectors which can routinely achieve 1 ppm accuracies (Bristow, 2006).…”
Section: A Electrostatic Acceleration Lensesmentioning
confidence: 94%
“…So, when unresolved isobaric ions are present in a sample the measured mass in TOF spectra will be an average, thereby reducing the mass accuracy to 10-20 ppm (the minimum required for elemental composition determination of steroids). Experimentally determined mass accuracies for stanozolol standard (i.e., no co-eluting isobaric interferences) at nominal m/z 329 were 12 and 0.4 ppm for the QqTOF and LTQ-FT-ICR, respectively (Nielen et al, 2007). The LTQ-Orbitrap has mass accuracy within 5 ppm (internal and external calibration) at m/z 400 (Makarov et al, 2006a,b;Olsen et al, 2005).…”
Section: B Metabolomicsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the use of narrow mass tolerance windows is only feasible when the mass spectrometer provides sufficient resolving power to discriminate analytes from isobaric co-eluting sample matrix compounds. It was predicted and demonstrated that a medium mass resolving power (Q)TOFMS(/MS) instrument might be critical in this respect [14]. The European Union (EU) recognizes the added value of high mass resolving power instruments for the identification of residues [15].…”
mentioning
confidence: 99%