2005
DOI: 10.1002/jms.873
|View full text |Cite
|
Sign up to set email alerts
|

Screening for unknown synthetic steroids in human urine by liquid chromatography‐tandem mass spectrometry

Abstract: Chemically modified steroids (designer steroids), including tetrahydrogestrinone and norbolethone, pose a threat to the integrity of the sport community. These compounds have recently been detected in urine specimens from athletes, resulting in temporary or permanent suspension from amateur and/or professional competition. Triple quadrupole mass spectrometers enable doping control laboratories to screen for unknown, anabolic, androgenic steroids utilizing precursor ion scans. On the basis of common dissociatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
95
0
2

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
4

Relationship

1
9

Authors

Journals

citations
Cited by 128 publications
(97 citation statements)
references
References 21 publications
0
95
0
2
Order By: Relevance
“…The analysis of the supplement was performed according to a previously described method (Parr et al, 2004). For the detection of tetrahydrogestrinone, stanozolol, metandienone and trenbolone, this method was adapted to liquid chromatographictandem mass spectrometric (LC/MS-MS) conditions, which are used for the detection of synthetic steroids in urine samples (Thevis et al, 2005). The limits of detection (signal/ noise ratio X3) of the listed steroids were calculated to be in the range of 0.2-5 ng g À1 .…”
Section: Methodsmentioning
confidence: 99%
“…The analysis of the supplement was performed according to a previously described method (Parr et al, 2004). For the detection of tetrahydrogestrinone, stanozolol, metandienone and trenbolone, this method was adapted to liquid chromatographictandem mass spectrometric (LC/MS-MS) conditions, which are used for the detection of synthetic steroids in urine samples (Thevis et al, 2005). The limits of detection (signal/ noise ratio X3) of the listed steroids were calculated to be in the range of 0.2-5 ng g À1 .…”
Section: Methodsmentioning
confidence: 99%
“…New metabolites of some anabolic steroids such as metandienone (Schänzer et al, 2006) or fluoxymesterone (Pozo et al, 2008d) were identified by LC-MS/MS. Triple quadrupole instruments seem to be ideal tools for this purpose because of the variety of scan modes that can be applied, including precursor ion scan (Thevis et al, 2005a;Schänzer et al, 2006;Pozo et al, 2008a,b) and neutral loss (Pozo et al, 2008b,d). Analyzers with accurate mass capabilities such as TOF or Orbitrap have also been incorporated in doping control analysis (Thevis et al, 2005b;Georgakopoulos et al, 2007;Kolmonen et al, 2007).…”
mentioning
confidence: 99%
“…Moreover, detection of unknown designer steroids is difficult in biological samples either using specific analysis or mass spectral library search, as both approaches would require establishing the analytical characteristics with suitable reference materials. [52][53][54] The detection strategies have been thoroughly reviewed elsewhere. [55] It is not uncommon that doping agents used in human sports would likewise be abused in equine sports.…”
Section: Nickelmentioning
confidence: 99%