“…The Fano-limited energy resolution (Δ E Fano ) is described by Equation (1): where F is the Fano factor and W is the electron hole pair creation energy; these have values of 0.1 and 4.62 eV ehp-1 in CdZnTe material [ 18 ]. In recent years, the spectroscopic performance of CdZnTe and CdTe detectors has improved dramatically, with FWHM measured at 59.54 keV of the order 1–2 keV [ 9 , 16 , 19 , 20 ], compared to the theoretical Fano-limited minimum of 0.39 keV.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Fano-limited energy resolution (Δ E Fano ) is described by Equation (1): where F is the Fano factor and W is the electron hole pair creation energy; these have values of 0.1 and 4.62 eV ehp-1 in CdZnTe material [ 18 ]. In recent years, the spectroscopic performance of CdZnTe and CdTe detectors has improved dramatically, with FWHM measured at 59.54 keV of the order 1–2 keV [ 9 , 16 , 19 , 20 ], compared to the theoretical Fano-limited minimum of 0.39 keV.…”
Section: Resultsmentioning
confidence: 99%
“…where F is the Fano factor and W is the electron hole pair creation energy; these have values of 0.1 and 4.62 eV ehp-1 in CdZnTe material [18]. In recent years, the spectroscopic performance of CdZnTe and CdTe detectors has improved dramatically, with FWHM measured at 59.54 keV of the order 1-2 keV [9,16,19,20], compared to the theoretical Fano-limited minimum of 0.39 keV. The spectroscopic performance of the HF-CdZnTe material was evaluated using the 241 Am sealed source as shown in Figure 4, where each channel of the spectra was 200 eV wide.…”
Section: Spectroscopic Performancementioning
confidence: 99%
“…What affect these individual design changes have on detector performance cannot be accurately separated. However, Acrorad CdTe detectors have over recent years been used in a large number of studies, achieving good results [ 29 , 30 , 31 ]. Coupled with the HEXITEC ASIC, excellent Full Width at Half Maximum (FWHM) energy resolution for single pixel events (0.75 keV at 59.5 keV across all pixels) has been achieved as well as good pixel count uniformity [ 29 ].…”
Section: Materials and Methodsmentioning
confidence: 99%
“…CCMod is designed to reproduce the response of most common configurations in medical applications composed of a scatterer and an absorber detectors working in time coincidence (Everett et al 1977). However, it can be adapted to accommodate other designs such as one single detector layer system that acts as scatterer and absorber at the same time (Lehner et al 2004, Mihailescu et al 2007, Maier et al 2018, Montémont et al 2017 frequently employed in homeland security applications.…”
Section: Compton Camera Modulesmentioning
confidence: 99%