2021
DOI: 10.3390/app11156725
|View full text |Cite
|
Sign up to set email alerts
|

Seismic and Energy Performance Evaluation of Large-Scale Curtain Walls Subjected to Displacement Control Fasteners

Abstract: Glass façade curtain walls in buildings is the façade system of choice in modern architecture of mid- to high-rise buildings. This study investigates the seismic and thermal insulation performance of curtain wall systems through structural analysis using the finite element method (FEM) and LBNL Window&Therm insulation analysis. The aim was to optimize the capability of the curtain wall module system and the fastener element technology to respond to displacement and vibration caused by dynamic seismic waves… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 25 publications
1
3
0
Order By: Relevance
“…This is in line with classical setup arrangements for literature experimental studies on curtain wall components, and even numerical investigation for vertical glass members [25,[60][61][62]. When possible, however, more complex setup configurations should be necessarily taken into account even for vertical load-bearing elements [63]. The vertical ground components should be definitely included for horizontal glass members (like slabs, roofs, or walkways that are sensitive to vertical vibrations [64]), in the same way of other constructional systems [65][66][67].…”
Section: Ground Motion and Intensity Measure (Im)supporting
confidence: 73%
“…This is in line with classical setup arrangements for literature experimental studies on curtain wall components, and even numerical investigation for vertical glass members [25,[60][61][62]. When possible, however, more complex setup configurations should be necessarily taken into account even for vertical load-bearing elements [63]. The vertical ground components should be definitely included for horizontal glass members (like slabs, roofs, or walkways that are sensitive to vertical vibrations [64]), in the same way of other constructional systems [65][66][67].…”
Section: Ground Motion and Intensity Measure (Im)supporting
confidence: 73%
“…In a synthesis framework, developed through the critical analysis of systems equipped with these devices, the hypothesis was put forward to evaluate the capacity of the façade to act as an energy absorption device [33], assuming the optimal value of the properties of the façade dampers. It is necessary, therefore, to advance knowledge in the systems of connections that move in the elastic-plastic field to guarantee, in-service conditions, their functionality, not only for the environmental requirements that influence the correct use of the building but also and above all to ensure the safety of the occupants.…”
Section: Experimentation Of Flexible Connectionmentioning
confidence: 99%
“…Force washers-The curtain wall façade relies on precisely torqued screws within a bracket system, which is essential for accurate positioning and optimal performance [36,37]. Therefore, an issue that could affect the life cycle of a structure could be bolt anomalies.…”
mentioning
confidence: 99%