2018
DOI: 10.26872/jmes.2018.9.1.8
|View full text |Cite
|
Sign up to set email alerts
|

Selective and sensitive detection of dopamine in the presence of ascorb ic acid and uric acid at a Sonogel - Carbon L - Histidine modified electrode

Abstract: Design and application of sensitive and selective electrochemical sensors for the determination of biologically important substances have gained considerable interest in recent years [1][2][3][4][5]. Dopamine (DA) is an important neurotransmitter molecule of catecholamines that is widely distributed in the mammalian central nervous system for message transfer. It plays a very important role in the function of central nervous, renal, hormonal, and cardio vascular systems [6]. Extreme abnormalities of DA levels … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…With regard to selectivity, after adding 10 µM of DA the current change of 8 nA was obtained; while after the same concentrations of glucose and AA were added, no significant change in the signal was observed. Atyah et al (2017) prepared a novel, simple, low-cost EC sensor to detect DA in the presence of AA and UA with high sensitivity and selectivity using a sonogel-carbon (SNGC) electrode which was modified with L-histidine (L-His SNGC) [113]. The electrocatalytic behavior of this innovative electrode towards DA oxidation was great in human serum and phosphate-buffered saline (PBS).…”
Section: Carbon-based Ec Sensormentioning
confidence: 99%
“…With regard to selectivity, after adding 10 µM of DA the current change of 8 nA was obtained; while after the same concentrations of glucose and AA were added, no significant change in the signal was observed. Atyah et al (2017) prepared a novel, simple, low-cost EC sensor to detect DA in the presence of AA and UA with high sensitivity and selectivity using a sonogel-carbon (SNGC) electrode which was modified with L-histidine (L-His SNGC) [113]. The electrocatalytic behavior of this innovative electrode towards DA oxidation was great in human serum and phosphate-buffered saline (PBS).…”
Section: Carbon-based Ec Sensormentioning
confidence: 99%
“…When DA redox peaks were compared with that from a mixture of DA and UA solutions (Fig. 5b), later revealed two distinctly separated anodic peaks of significantly enhanced current intensity (Atyah et al 2017) and was attributed to the increased concentration of DA-UA solution (Nayak et al 2016). This was confirmed by the disappearance of AA peaks when similar experiments were conducted with DA and AA mixture solutions (Fig.…”
Section: Resultsmentioning
confidence: 99%