2018
DOI: 10.1117/1.jbo.23.11.115002
|View full text |Cite
|
Sign up to set email alerts
|

Selective retina therapy: toward an optically controlled automatic dosing

Abstract: Selective retina therapy (SRT) targets the retinal pigment epithelium (RPE) with pulsed laser irradiation by inducing microbubble formation (MBF) at the intracellular melanin granula, which leads to selective cell disruption. The following wound healing process rejuvenates the chorio-retinal junction. Pulse energy thresholds for selective RPE effects vary intra-and interindividually. We present the evaluation of an algorithm that processes backscattered treatment light to detect MBF as an indicator of RPE cell… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
33
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 32 publications
(35 citation statements)
references
References 29 publications
1
33
0
1
Order By: Relevance
“…Neither reference grids for DME nor well localized circles or patterns in CSR treatment can be placed due to lack of visual feedback. On the other hand, with respect to proper energy dosage, studies showed a strong inter-and intraindividual variation of the necessary pulse energies for comparable RPE effects [63,64]. Even with titration at the arcades, angiography after treatment is required to ensure RPE defects due to the variability of the absorption.…”
Section: Clinical Study Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Neither reference grids for DME nor well localized circles or patterns in CSR treatment can be placed due to lack of visual feedback. On the other hand, with respect to proper energy dosage, studies showed a strong inter-and intraindividual variation of the necessary pulse energies for comparable RPE effects [63,64]. Even with titration at the arcades, angiography after treatment is required to ensure RPE defects due to the variability of the absorption.…”
Section: Clinical Study Resultsmentioning
confidence: 99%
“…Typically, an annular shaped piezoelectric ultrasonic transducer is embedded in the contact lens, which is used anyway for laser treatments utilizing a laser slit lamp [73]. Figure 11.7b (blue curves) show such transients when using SRT at low radiant exposures [64]. Since the pressure is proportional to the pulse energy, all transients are almost identical when normalizing on the energy (Fig.…”
Section: (A) Optoacousticsmentioning
confidence: 98%
See 3 more Smart Citations