2015
DOI: 10.1039/c5ay00468c
|View full text |Cite
|
Sign up to set email alerts
|

Self-assembly pipette tip-based cigarette filters for micro-solid phase extraction of ketoconazole cis-enantiomers in urine samples followed by high-performance liquid chromatography/diode array detection

Abstract: A simple stereoselective HPLC/DAD method was developed for the determination of ketoconazole (KTZ) cis-enantiomers in human urine.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 29 publications
(8 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…27 Analyzing the CF spectrum, the band at approximately 3500 cm À1 can be assigned to O-H stretching, 1750 cm À1 to C]O stretching and 1245 cm À1 to C-O stretching; all of these bands are characteristic of CF for being an ester with hydroxyl groups from the cellulose. 21 With the characterization of the main bands of PAni and CF, we verify that the PAni-CF composite spectrum is the sum of the PAni and CF spectra, differing only in intensity and with a small displacement of some bands owing to interference of the bands related to the separated material. From the SEM characterization ( Fig.…”
Section: Characterization Of the Adsorbents Materialsmentioning
confidence: 60%
See 1 more Smart Citation
“…27 Analyzing the CF spectrum, the band at approximately 3500 cm À1 can be assigned to O-H stretching, 1750 cm À1 to C]O stretching and 1245 cm À1 to C-O stretching; all of these bands are characteristic of CF for being an ester with hydroxyl groups from the cellulose. 21 With the characterization of the main bands of PAni and CF, we verify that the PAni-CF composite spectrum is the sum of the PAni and CF spectra, differing only in intensity and with a small displacement of some bands owing to interference of the bands related to the separated material. From the SEM characterization ( Fig.…”
Section: Characterization Of the Adsorbents Materialsmentioning
confidence: 60%
“…19,20 Actually, it is desirable to monitor and to develop analytical methodologies to detect and control the presence of pharmaceuticals in very different kinds of samples, for example waste water, urine, serum or plasma, most of which are very complex matrices. 21,22 Thus the development of new adsorbent materials to employ in techniques of sample extraction is highly desired.…”
Section: Introductionmentioning
confidence: 99%
“…Accordingly, 1000 μL of water samples was selected for the following experiments because it showed better recovery which was also the case with Andrade et al. .…”
Section: Resultsmentioning
confidence: 92%
“…SPE is the most widely used procedure for the extraction of analytes from different samples . Several SPE approaches can be found in literature using cartridges , columns , fibers and pipette‐tips .…”
Section: Introductionmentioning
confidence: 99%
“…Selective extractions were obtained with limits of detection <0.5 μg/L. Borges and coauthors developed tip‐based pipettes on MIPs for the extraction of ketoconazole and fluoroquinolones from urine samples. The MIP selectivity was attested and the limits of detection were lower than 40 μg/L.…”
Section: Introductionmentioning
confidence: 99%