Abstract:Simultaneously, the p-synephrine 1 template was imprinted, and a ferrocene redox probe was covalently immobilized in a (bis-bithiophene)-based polymer, and the resulting molecularly imprinted polymer (MIP) was deposited on the Pt electrode as a thin film to form a redox self-reporting MIP film-based chemosensor. After subsequent template extraction from the film, analyte 1 was determined with differential pulse voltammetry (DPV) in a (redox probe)-free solution. That was possible because the internal ferrocene… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.