2017
DOI: 10.3389/fnins.2017.00033
|View full text |Cite
|
Sign up to set email alerts
|

sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand

Abstract: One of the greatest challenges of using a myoelectric prosthetic hand in daily life is to conveniently measure stable myoelectric signals. This study proposes a novel surface electromyography (sEMG) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy electrodes) to allow people with disabilities to control prosthetic limbs. The PPy electrodes are sewn on an elastic band to guarantee close contact with the skin and thus reduce the contact electrical impedance between the electrodes and the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 34 publications
(28 citation statements)
references
References 51 publications
0
27
0
Order By: Relevance
“…Concerning their electrical conductivity, PEDOT-PSS-coated textile electrodes showed a resistance of 35 kX at 100 Hz. 55 The PPy-based electrode reported by Jiang et al 56 has a surface resistivity <1 Â 10 5 X/sq, which is lower than that of PEDOT-PSS. However, PPy exhibits low water solubility and hygroscopicity in the ambient environment; therefore, when the electrodes become wet or humid due to skin perspiration, they may provide a more stable performance making them usable in daily life.…”
Section: Textile-based Electrodes For Long-term/continuous Semg Recormentioning
confidence: 96%
See 4 more Smart Citations
“…Concerning their electrical conductivity, PEDOT-PSS-coated textile electrodes showed a resistance of 35 kX at 100 Hz. 55 The PPy-based electrode reported by Jiang et al 56 has a surface resistivity <1 Â 10 5 X/sq, which is lower than that of PEDOT-PSS. However, PPy exhibits low water solubility and hygroscopicity in the ambient environment; therefore, when the electrodes become wet or humid due to skin perspiration, they may provide a more stable performance making them usable in daily life.…”
Section: Textile-based Electrodes For Long-term/continuous Semg Recormentioning
confidence: 96%
“…Four articles did not specify the size of the electrodes, and three articles reported adjustable electrode size. 56,57,61 The orientation of the electrode with respect to the muscle fiber was poorly described in the reviewed literature, although the orientation is of importance.…”
Section: Electrode Configurationmentioning
confidence: 99%
See 3 more Smart Citations