2009
DOI: 10.1016/j.compmedimag.2009.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Semi-automated method for brain hematoma and edema quantification using computed tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
32
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(32 citation statements)
references
References 23 publications
0
32
0
Order By: Relevance
“…dx Imaging modality Current hematoma yes yes no yes CT CBMS98 [8] hematoma N/D yes no NO CT SPIE99 [9] hematoma yes yes no NO CT CIARP07 [10] hematoma N/D yes no NO CT CMIG07 [11] hematoma NO NO YES yes CT JNT08 [12] hematoma yes N/D N/D yes CT EMBS08 [13] hematoma yes yes no N/D CT CMIG09 [14] hematoma yes yes no NO CT AJNR01 [15] stroke NO no yes NO CT EMBS04 [16] stroke N/D yes NO NO MRI (DWI) MIAR04 [17] stroke yes no yes NO MRI qualitative diagnosis. Section 5 will focus on hematoma volume measurement at the original resolution using a multiresolution binary level set method.…”
Section: Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…dx Imaging modality Current hematoma yes yes no yes CT CBMS98 [8] hematoma N/D yes no NO CT SPIE99 [9] hematoma yes yes no NO CT CIARP07 [10] hematoma N/D yes no NO CT CMIG07 [11] hematoma NO NO YES yes CT JNT08 [12] hematoma yes N/D N/D yes CT EMBS08 [13] hematoma yes yes no N/D CT CMIG09 [14] hematoma yes yes no NO CT AJNR01 [15] stroke NO no yes NO CT EMBS04 [16] stroke N/D yes NO NO MRI (DWI) MIAR04 [17] stroke yes no yes NO MRI qualitative diagnosis. Section 5 will focus on hematoma volume measurement at the original resolution using a multiresolution binary level set method.…”
Section: Systemmentioning
confidence: 99%
“…There has been a couple of CAD systems for brain images in the literature, most of them are used to diagnose intracranial hematoma [8][9][10][11][12][13][14] or ischemic stroke [15][16][17]. A brief summery is given in Table 1.…”
Section: Related Workmentioning
confidence: 99%
“…This technique uses minimal user input to identify IVH, and can give a very accurate measure of the total volume of the segmented structure. 29 However, this method requires sophisticated software that is not validated, nor is it readily available in most clinical settings. Using our proposed methods, the CT scan is all that is required to assign the mGS.…”
Section: Discussionmentioning
confidence: 99%
“…As shown in [5], misinterpretation of CT in patients with SAH is a common problem. Various hemorrhage detection systems have been reported [6][7][8][9][10], but none of them are suitable for the detection of SAH. These methods have two common assumptions: the hemorrhagic region in brain CT being hyperdense, and asymmetric.…”
Section: Introductionmentioning
confidence: 99%