2005
DOI: 10.1016/j.jaap.2004.09.008
|View full text |Cite
|
Sign up to set email alerts
|

Semivolatile and volatile compounds from the pyrolysis and combustion of polyvinyl chloride

Abstract: Emissions evolved from the pyrolysis and combustion of poly(vinyl chloride) were studied at four different temperatures (500, 700, 850 and 1000 8C) in a horizontal laboratory tubular quartz reactor in order to analyse the influence of both temperature and reaction atmosphere on the final products from thermal and oxidative reactions. It was observed that the CO 2 /CO ratio increased with temperature. Methane was the only light hydrocarbon whose yield increased with temperature up to 1000 8C. Benzene was rather… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
69
0
1

Year Published

2006
2006
2022
2022

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 89 publications
(76 citation statements)
references
References 36 publications
6
69
0
1
Order By: Relevance
“…Pyrolysis and combustion runs were conducted with both samples at two different temperatures (600 and 850 ºC), using a tubular quartz reactor located inside a horizontal laboratory furnace described in detail elsewhere (Aracil et al, 2005a). For each run, synthetic air (combustion runs) or nitrogen (pyrolysis runs) was introduced in parallel flow with respect to the sample, at a constant flow of 300 mL/min (1 atm, 20 ºC).…”
Section: Methodsmentioning
confidence: 99%
“…Pyrolysis and combustion runs were conducted with both samples at two different temperatures (600 and 850 ºC), using a tubular quartz reactor located inside a horizontal laboratory furnace described in detail elsewhere (Aracil et al, 2005a). For each run, synthetic air (combustion runs) or nitrogen (pyrolysis runs) was introduced in parallel flow with respect to the sample, at a constant flow of 300 mL/min (1 atm, 20 ºC).…”
Section: Methodsmentioning
confidence: 99%
“…PVC resin Etinox-450 free of additives obtained by emulsion polymerization: had a medium molecular weight (104,000 and 40,000 for Mw and Mn, respectively) and very small particle size, ranging from 1.4 to 24.4 mm [4].…”
Section: Methodsmentioning
confidence: 99%
“…After collecting the exit gas for 5 min, the holder was removed from the furnace. More details regarding the experimental procedure can be found elsewhere [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16].…”
Section: Methodsmentioning
confidence: 99%
“…This equipment has been previously described in detail (Aracil et al, 2005;Moltó et al, 2011). For each run, nitrogen was introduced at a constant flow of 300 mL min −1 in parallel to the sample movement.…”
Section: Furnace For Pyrolysis Runsmentioning
confidence: 99%