2012
DOI: 10.4172/2155-6210.1000115
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive Detection of TNT using Competition Assay on Quartz Crystal Microbalance

Abstract: Currently available TNT sensors are characterized by high sensitivity, but low specificity, which limits the detection of TNT in dirty environments. We report here a TNT sensor designed to measure the displacement of a TNT-specific antibody by quartz crystal microbalance (QCM). This sensor combines high sensitivity of detection (0.1 ng/mL) with the ability to distinguish TNT from molecules with similar chemical properties. Particularly, the reliability of this method for the detection of TNT in dirty environme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 52 publications
0
10
0
Order By: Relevance
“…where q is the fraction of the SLBs with attached polymer and (1 À q) represents the sites available for further polymer association. Dening K A as the ratio of k A to k ÀA , the following equation describes the relationship between the polymer concentration and the surface stress change measured on the cantilever (a detailed derivation has been previously reported 53 and is shown in the ESI †):…”
Section: Fluorescence Recovery Aer Photobleaching (Frap)mentioning
confidence: 99%
See 1 more Smart Citation
“…where q is the fraction of the SLBs with attached polymer and (1 À q) represents the sites available for further polymer association. Dening K A as the ratio of k A to k ÀA , the following equation describes the relationship between the polymer concentration and the surface stress change measured on the cantilever (a detailed derivation has been previously reported 53 and is shown in the ESI †):…”
Section: Fluorescence Recovery Aer Photobleaching (Frap)mentioning
confidence: 99%
“…18 This model has been previously used to describe the binding between antigenantibody systems on microcantilevers. 43,53 The association constant K A is calculated using eqn (6). Fig.…”
Section: Mathematical Modeling and Calculation Of The Association Conmentioning
confidence: 99%
“…As a number of literature reports show (Pathirana et al 2000;Wang et al 2012), the use of QCM allows the detection of pathogens and contaminants using sensors modified with immobilized antibodies. As a number of literature reports show (Pathirana et al 2000;Wang et al 2012), the use of QCM allows the detection of pathogens and contaminants using sensors modified with immobilized antibodies.…”
Section: Piezoelectric Biosensorsmentioning
confidence: 99%
“…(7) To date, great progress has been made, and devices such as quartz crystal microbalance (QCM) and techniques including square wave voltammetry (SWV), electrochemical impedance spectroscopy (EIS), and colorimetric method have been used for the detection of nitroaromatic compounds in both liquid and vapor phases. (8)(9)(10)(11)(12) In particular, field-effect transistor (FET)based biosensors have been considered in the detection of nitrates and some small molecules because of their easy integration, low cost, and high throughput with the target receptor functionalized on the semiconducting layers. (2,4,5) FET-based potentiometric biosensing detects the concentration of biomolecules captured on a semiconducting gate electrode, where the charged biomolecules change the carrier concentration.…”
Section: Introductionmentioning
confidence: 99%