2020
DOI: 10.1016/j.microc.2019.104372
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive spectrofluorimetric assay based on micelle enhanced protocol for the determination of hepatitis C antiviral agent (simeprevir): Application to dosage form and human plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 17 publications
0
10
0
Order By: Relevance
“…The resolution of the overlaid spectra was allowed by using Δλ value of 90 nm, which is not equal to the difference between the emission and excitation wavelengths of the two drugs. Therefore, the sensitivity of the proposed method is slightly lower than the native estimation reported in the literature 9,25 . However, it is higher than another fluorimetric method reported for SIM 25 .…”
Section: Limit Of Quantitation (Loq) and Limit Of Detection (Lod)mentioning
confidence: 61%
See 2 more Smart Citations
“…The resolution of the overlaid spectra was allowed by using Δλ value of 90 nm, which is not equal to the difference between the emission and excitation wavelengths of the two drugs. Therefore, the sensitivity of the proposed method is slightly lower than the native estimation reported in the literature 9,25 . However, it is higher than another fluorimetric method reported for SIM 25 .…”
Section: Limit Of Quantitation (Loq) and Limit Of Detection (Lod)mentioning
confidence: 61%
“…Accuracy and precision. The suggested method's accuracy was confirmed by statistically analyzing the obtained data compared to those obtained using reference methods 9,25 . The Student t-test and the Variance ratio F-test were used to statistically examine the data 43 .…”
Section: Limit Of Quantitation (Loq) and Limit Of Detection (Lod)mentioning
confidence: 80%
See 1 more Smart Citation
“…[ 23 ] This strategy has been utilized to enhance the sensitivity of fluorimetry of many pharmaceutical compounds. [ 24–26 ] MTX in aqueous solution has weak original fluorescence properties at 675 nm if excited at 610 nm (Figure 1). Different surfactants and macromolecules were examined for their ability to strengthen the weak MTX fluorescence emission.…”
Section: Resultsmentioning
confidence: 99%
“…The literature review of SMV [9] , [10] , [11] , [12] , [13] and SFV [14] , [15] , [16] , [17] , [18] revealed few published methods for determination of the drugs individually. There were only two published methods for the simultaneous determination goal [19] , [20] .…”
Section: Introductionmentioning
confidence: 99%