Sensitivity analysis of a cemented hip stem to implant position and cement mantle thickness

Abstract: Patient-specific finite element models of the implanted proximal femur can be built from pre-operative computed tomography scans and post-operative X-rays. However, estimating three-dimensional positioning from two-dimensional radiographs introduces uncertainty in the implant position. Further, accurately measuring the thin cement mantle and the degree of cement -bone interdigitation from imaging data is challenging. To quantify the effect of these uncertainties in stem position and cement thickness, a sensiti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
1

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 57 publications
0
6
0
1
Order By: Relevance
“…Очевидно, что пе-речисленные факторы не относятся к неустра-нимым, и если учитывать их при планировании, то, вероятно, вполне можно избежать. Несмотря на то, что доля ревизий по поводу расшатывания цементных бедренных компонентов являлась низкой, а очевидных причин ревизии на рентге-нограммах выявить не удалось, мы считаем, что их раннее расшатывание могло быть связано с нарушением техники установки имплантатов, в частности, формирования неадекватной мантии или выбора несоответствующего размера нож-ки эндопротеза [26,30].…”
Section: -2 (72)unclassified
“…Очевидно, что пе-речисленные факторы не относятся к неустра-нимым, и если учитывать их при планировании, то, вероятно, вполне можно избежать. Несмотря на то, что доля ревизий по поводу расшатывания цементных бедренных компонентов являлась низкой, а очевидных причин ревизии на рентге-нограммах выявить не удалось, мы считаем, что их раннее расшатывание могло быть связано с нарушением техники установки имплантатов, в частности, формирования неадекватной мантии или выбора несоответствующего размера нож-ки эндопротеза [26,30].…”
Section: -2 (72)unclassified
“…The cement mantle is also made up of two distinct layers, one of pure bone cement and the other a composite layer of cement and cancellous bone. At the macro-scale this is difficult to model and as a consequence only a few studies have considered it as a composite layer (Shi et al, 2013). The majority of studies also assume that the bone-cement interface is rigidly bonded.…”
Section: Simulation Of the Initial Mechanical Environment Of The Bonementioning
confidence: 99%
“…The method allows for large numbers of parameters (P) to be explored at a fixed number of levels (N). For full factorial designs (Clarke et al, 2011(Clarke et al, , 2012) the number of required analyses is P N , but by implementing fractional factorial designs (e.g Taguchi method) the number of analyses can be substantially reduced whilst still extracting the required information (Shi et al, 2013;Ong et al, 2006;Amiri and Wilson, 2012;Bahraminasab et al, 2013Bahraminasab et al, , 2014. Through careful study design, it is possible to explore both design related and environmental, patient and surgery related variability.…”
Section: Design Of Computer Based Experimentsmentioning
confidence: 99%
“…Combination of the FE solvers with probabilistic methods (i.e. probabilistic FE analyses) have been applied to reliability of other orthopaedic components such as hip replacements [13][14][15][16] and for a longer time in the assessment of structural reliability [17][18][19]. This combination results in a more rigorous validation of the computation model and a more realistic comparison of the predicted results with results obtained by other means such as experimental results [11,12].…”
Section: Introductionmentioning
confidence: 99%