2000
DOI: 10.1016/s0926-4345(00)80065-6
|View full text |Cite
|
Sign up to set email alerts
|

Separation and preconcentration of elements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
64
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 98 publications
(64 citation statements)
references
References 148 publications
0
64
0
Order By: Relevance
“…1,10-Phenanthroline, 2,4,6-tris(2-pyridyl)-s-triazine (TPTZ), sodium salicylate, ferrous ammonium sulphate hexahydrate, ferric ammonium sulphate dodecahydrate, and L-ascorbic acid were also used. Standard solutions for the determination of iron using phenanthroline, [32][33][34][35] TPTZ, 35,36 and salicylate 37 were prepared according to standard/reference methods.…”
Section: Materials and Reagentsmentioning
confidence: 99%
See 1 more Smart Citation
“…1,10-Phenanthroline, 2,4,6-tris(2-pyridyl)-s-triazine (TPTZ), sodium salicylate, ferrous ammonium sulphate hexahydrate, ferric ammonium sulphate dodecahydrate, and L-ascorbic acid were also used. Standard solutions for the determination of iron using phenanthroline, [32][33][34][35] TPTZ, 35,36 and salicylate 37 were prepared according to standard/reference methods.…”
Section: Materials and Reagentsmentioning
confidence: 99%
“…A 1 mL portion of each of the ascorbic acid, phenanthroline and acetic/acetate buffer solution (pH 4.0) were added, and the ask was completed to the mark with water, mixed well, and set aside for 15 min to allow for full colour development. [32][33][34][35] A portion of the mixed solution was transferred to a 10 mm spectrophotometric cell, and the absorbance at 512 nm was measured against a similarly prepared blank. The same sample and blank cells were then transferred to our homemade platform to capture digital images using the Canon digital camera and the Sony smartphone.…”
Section: Instruments and Sowarementioning
confidence: 99%
“…To avoid the analytical interferences between the investigated elements, each element was measured selectively by the following corresponding method 24 : The concentration of Fe (III), Zr (IV), Th (IV) and Ce (III) in the aqueous phase was determined by spectrophotometric thiocyanate (arsenazo III, HCl), Thoron I and (arsenazo III, formate buffer) method at the wavelength 495, 665, 540 and 650 nm, respectively.…”
Section: Spectrophotometric Measurements Of Fe (Iii) Zr (Iv) Th (Ivmentioning
confidence: 99%
“…(Weltz and Sperling 1999) [8]. A spectrophotometric method using a double-beam UV-Visible Shimadzu (model 160A) was applied for REE where they form stable colored complex with Arsenazo III in weakly acidic media at pH about 2.6 and the absorbance me-asured at wavelength 650 nm against a reagent bla-nk solution (Marczenko,1986) [9]. Ca and Mg were determined by a titrimetric method using EDTA.…”
Section: Analytical Proceduresmentioning
confidence: 99%