2011
DOI: 10.1007/s00198-011-1789-5
|View full text |Cite
|
Sign up to set email alerts
|

Serum adiponectin and bone mineral density in male hemodialysis patients

Abstract: Increased levels of serum adiponectin were associated with decrease in BMD in male hemodialysis patients. Adiponectin may play a role in mineral and bone disorder, possibly in bone resorption, of patients with CKD 5D.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
25
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 35 publications
(27 citation statements)
references
References 47 publications
1
25
0
1
Order By: Relevance
“…As serum bone resorption markers, serum cross-linked N-telopeptide of type I collagen (NTX) and C-terminal telopeptide of type I collagen (CTX) were measured. Serum NTX was measured by ELISA (Osteomark NTX serum; Ostex International, Seattle, WA, USA), with an intra-assay CV of 4.6%, as reported previously [22,23]. Serum CTX was determined by means of the Elecsys β-CrossLaps/serum assay (Roche Diagnostics, Mannheim, Germany), which is a sandwich immunoassay with two monoclonal antibodies specific for the β-isomerized 8-amino acid sequence of the C-terminal telopeptide of type I collagen [24].…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…As serum bone resorption markers, serum cross-linked N-telopeptide of type I collagen (NTX) and C-terminal telopeptide of type I collagen (CTX) were measured. Serum NTX was measured by ELISA (Osteomark NTX serum; Ostex International, Seattle, WA, USA), with an intra-assay CV of 4.6%, as reported previously [22,23]. Serum CTX was determined by means of the Elecsys β-CrossLaps/serum assay (Roche Diagnostics, Mannheim, Germany), which is a sandwich immunoassay with two monoclonal antibodies specific for the β-isomerized 8-amino acid sequence of the C-terminal telopeptide of type I collagen [24].…”
Section: Methodsmentioning
confidence: 99%
“…The serum samples were stored in aliquots at −20°C until subsequent assay of bone metabolism markers, with measurements made immediately after thawing. The serum biochemical parameters for bone metabolism were determined, as described previously [22,23,24,25]. All serum bone markers were measured in the same assay run, in order to avoid inter-assay variance.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations