2011
DOI: 10.1016/j.steroids.2010.11.005
|View full text |Cite
|
Sign up to set email alerts
|

Serum steroid profiling by isotopic dilution-liquid chromatography–mass spectrometry: Comparison with current immunoassays and reference intervals in healthy adults

Abstract: Our ID-LC-MS/MS method proved to be reliable and sensitive in revealing steroid circulating concentrations in adults and in highlighting the limits of routine immunoassays at low concentrations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

26
142
4
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 174 publications
(173 citation statements)
references
References 35 publications
26
142
4
1
Order By: Relevance
“…Immunoassays tend to overestimate the serum concentration of Adione when compared to LC-MS/MS based assays [6], which was also the case in this study (see Fig. 4B).…”
Section: Sample Preparation Referencessupporting
confidence: 76%
“…Immunoassays tend to overestimate the serum concentration of Adione when compared to LC-MS/MS based assays [6], which was also the case in this study (see Fig. 4B).…”
Section: Sample Preparation Referencessupporting
confidence: 76%
“…Measurement of DHEAS, a hormone of predominantly adrenal origin in women, is not routinely required, although when a neoplastic source of androgen excess is suspected a very high DHEAS concentration may be predictive of an androgen-secreting adrenal cancer (19). The evaluation of steroid hormone profiles, by using liquid chromatography combined with tandem mass spectrometry, a recent technique displaying good precision, sensitivity, and high accuracy, would greatly improve the assessment of androgen excess in patients with PCOS (20,21,22,23).…”
Section: European Journal Of Endocrinologymentioning
confidence: 99%
“…Briefly, samples were purified by solid-phase extraction and injected into a Serie 200 HPLC (PerkinElmer) configured in a two-dimensional LC consisting of a first purification on a perfusion column and a second separation on a Luna RP-C8 100 × 4.6 mm, 5 μm (Phenomenex, Torrance, CA, USA) (22). Afterward, analytes underwent atmospheric pressure chemical ionization and multiple reaction monitoring detection by an API4000 QTrap mass spectrometer (AB SCIEX, Toronto, ON, Canada) (22). Intra-and inter-assay coefficient of variation (CV) were <10 and <11%, respectively, and accuracy ranged between 83.7 and 106.2% for all the analytes (22).…”
Section: Laboratory Analysesmentioning
confidence: 99%
“…Afterward, analytes underwent atmospheric pressure chemical ionization and multiple reaction monitoring detection by an API4000 QTrap mass spectrometer (AB SCIEX, Toronto, ON, Canada) (22). Intra-and inter-assay coefficient of variation (CV) were <10 and <11%, respectively, and accuracy ranged between 83.7 and 106.2% for all the analytes (22). The sensitivity in serum matrix was 0.156 nmol/L (0.049 ng/mL) for P, 0.236 nmol/L (0.078 ng/mL) for 17OHP, 2.70 nmol/L (0.78 ng/mL) for DHEA, 0.136 nmol/L (0.039 ng/mL for A, and 0.066 nmol/L (0.019 ng/mL) for TS (22).…”
Section: Laboratory Analysesmentioning
confidence: 99%
See 1 more Smart Citation