2017
DOI: 10.1007/978-981-10-3953-9_30
|View full text |Cite
|
Sign up to set email alerts
|

Server Utilization-Based Smart Temperature Monitoring System for Cloud Data Center

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…At this juncture, therefore, presence of appropriate Cloud Computing monitoring system takes on an increased significance. In research studies [8] [9], the authors discuss and propose methods to streamline power consumption using algorithms that balance server loads in Cloud Computing data centers. Incidentally, the aspect of data retrieval also begins to take on a greater significance when taken in context of many millions of users who rely on Cloud Computing to store data.…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…At this juncture, therefore, presence of appropriate Cloud Computing monitoring system takes on an increased significance. In research studies [8] [9], the authors discuss and propose methods to streamline power consumption using algorithms that balance server loads in Cloud Computing data centers. Incidentally, the aspect of data retrieval also begins to take on a greater significance when taken in context of many millions of users who rely on Cloud Computing to store data.…”
Section: Related Workmentioning
confidence: 99%
“…As noted and documented in research conducted [11], for Cloud Computing data centers to conserve power at every possible stage, power usage and heat sensitivity issues need to be addressed. Research studies [8] [9] concluded that rationalizing power consumption and, thus, bring in degree of control over heat emissions resulting from peak loads on servers, can be possible using proposed load balancing techniques. In tandem with how server load balancing optimization is approached, considering that Cloud Computing networks has to handle search requests from system applications, software, or direct consumer requests, search engine optimization is considered extremely important.…”
Section: Related Workmentioning
confidence: 99%
“…Moreover, trace-driven experiments have been conducted on real clouds to test the performance of WAGS technique and experimental results show that the proposed technique performs effectively in terms of energy consumption and latency. Sahana et al [152] proposed a Server Utilization-based Smart Temperature Monitoring (SUSTM) technique, which maintains the cooling of CDC. In this technique, the concept of Mean Utilization Factor is used to find and control the amount of cool air to maintain the operating temperature in and around the servers within a CDC.…”
Section: Related Studiesmentioning
confidence: 99%
“…Based on existing literature [150][151][152][153][154][155], cooling management consists of the following components: i) cooling management techniques and ii) cooling plant as shown in Figure 25. Each of these taxonomy elements are discussed below along with relevant examples.…”
Section: Cooling Management Based Taxonomymentioning
confidence: 99%
“…There are various methods which help to bring down rise in temperatures of servers in cloud data center infrastructure. Sahana et all, approached the problem in a new lightconcentrating on server utilization to regulate the temperature [9]. They introduced Mean Utilization Factor concept that allows detecting and regulating the amount of cool air that is to be channelled in and around the servers within a cloud data center to bring down the operating temperature…”
Section: Literature Reviewmentioning
confidence: 99%