2021
DOI: 10.1186/s12886-021-01963-x
|View full text |Cite
|
Sign up to set email alerts
|

Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation

Abstract: Background To describe the very early vault changes in the first month after Implantable Collamer Lens (ICL) implantation and to evaluate the effect of preoperative biometric factors on vault. Methods Eighty-three eyes from eighty-three subjects with complete data who met follow-up requirements were recruited in this retrospective study between May 2019 and March 2020. We quantitatively assessed the postoperative vault at 2 h, 1 day, 1 week, and 1 … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
21
2
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(28 citation statements)
references
References 43 publications
3
21
2
2
Order By: Relevance
“…At 1 month after surgery, ICL size had the greatest impact on the arch height, followed by horizontal sulcus-to-sulcus diameter (STS), crystalline lens thickness (LT), and vertical STS. The influence of other factors such as white-to-white diameter (WTW) and preoperative spherical equivalent refractive error had no effect [55][56][57][58]. Although WTW can indirectly predict STS, the WTW diameter was further away from 11.08 to 12.51 mm, or the ACD was further away from 2.81 to 3.74 mm, the correlation between the STS and WTW diameters was weaker [59].…”
Section: Abnormality Of Arch Heightmentioning
confidence: 99%
“…At 1 month after surgery, ICL size had the greatest impact on the arch height, followed by horizontal sulcus-to-sulcus diameter (STS), crystalline lens thickness (LT), and vertical STS. The influence of other factors such as white-to-white diameter (WTW) and preoperative spherical equivalent refractive error had no effect [55][56][57][58]. Although WTW can indirectly predict STS, the WTW diameter was further away from 11.08 to 12.51 mm, or the ACD was further away from 2.81 to 3.74 mm, the correlation between the STS and WTW diameters was weaker [59].…”
Section: Abnormality Of Arch Heightmentioning
confidence: 99%
“…For concave shape iris, it had a tendency to demonstrate low vault value after ICL implantation; while for convex shape iris, most of eyes acquired a high vault value. With regards to the parameters about the lens, previous studies have reported that the LT and LR had significantly negative correlation with vault value in previous studies ( 10 , 11 , 19 , 20 ). However, eyes in our study obtained both high and low vault value even though they all had the LT > 4.0 mm.…”
Section: Discussionmentioning
confidence: 80%
“…Herein, the iris shape demonstrated significant correlation with the vault value. As is known, the ICL size had a positive association with postoperative vault ( 11 ). Therefore, it seemed rational to choose a relative larger size ICL when facing the increased LT or LR.…”
Section: Discussionmentioning
confidence: 92%
See 2 more Smart Citations