Abstract:Breath sensing system based on cavity ring-down spectroscopy (CRDS) technique is attractive due to its real time sensing in addition to the capability of high sensitivity. Utilizing waveguide for CRDS may realize ppm-order components into a compact area. This work have exploited thermal oxidation technique to silicon high-mesa waveguides for sensing-application. Significant propagation loss reduction from 1.45 to 0.84 dB/cm at a waveguide width of 500 nm has been achieved by the technique successfully.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.