2022
DOI: 10.1039/d1ay02031e
|View full text |Cite
|
Sign up to set email alerts
|

Silver-doped hydroxyapatite for formaldehyde determination by digital-image colorimetry

Abstract: Silver-hydroxyapatite material (Ag-HAP) was first proposed as material for trace-level formaldehyde detection based on Tollens’ reaction on the material surface. By using this Ag-HAP material, the chemical reduction caused by...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 36 publications
0
4
0
Order By: Relevance
“…The bands of 3d 3/2 and 3d 5/2 can be deconvoluted into two peaks. The peaks at 374.35 and 368.35 eV correspond to elemental silver, while the peaks at 373.9 and 367.9 eV, slightly lower in binding energy compared to those for elemental silver, indicate the presence of silver associated with oxygen in Ag 2 O . When sodium borohydride was added to the aqueous bath used to strip the AgNW films from filter papers, the oxygen content on the surface of the as-prepared AgNWs was significantly reduced (Figure a).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The bands of 3d 3/2 and 3d 5/2 can be deconvoluted into two peaks. The peaks at 374.35 and 368.35 eV correspond to elemental silver, while the peaks at 373.9 and 367.9 eV, slightly lower in binding energy compared to those for elemental silver, indicate the presence of silver associated with oxygen in Ag 2 O . When sodium borohydride was added to the aqueous bath used to strip the AgNW films from filter papers, the oxygen content on the surface of the as-prepared AgNWs was significantly reduced (Figure a).…”
Section: Resultsmentioning
confidence: 99%
“…It is worth noting that the use of Ag top electrodes in PSCs leads to lower efficiency compared to those with Au electrodes due to the smaller WF, lower reflectivity, and higher contact resistance. 55,56 However, PSCs with pristine AgNW electrodes exhibit very poor photovoltaic performance with a PCE of 4.25%, even lower than that of PSCs with the T-Ag electrode.…”
Section: Resultsmentioning
confidence: 99%
“…Formaldehyde in an alkaline environment reduces silver ions, which leads to the precipitation of silver nanoparticles (AgNPs-HAP), which in turn changes the color of the sensor from whitish to pale yellow to dark brown depending on the concentration of formaldehyde. In order to more accurately determine the concentration of formaldehyde without analytical instruments, the ability to assess the color intensity of the sensor was developed thanks to the ImageJ software, which analyzes a photo of the sensor taken with a smartphone [ 72 ]. The next sensor, based on o-phenylenediamine (OPD) substrate on MnO 2 nanosheets, enabled the detection of formaldehyde in air, food samples, and beer using a fluorometric method.…”
Section: Electrochemical Sensors For the Detection Of Chemical Carcin...mentioning
confidence: 99%
“…Several research studied the use of Ag-doped HA for various medical devices; for example, they are used as a bone implant with an improved osteoconductivity [ 6 ], and as bioceramic layers with antifungal and antibacterial properties [ 7 , 8 ]. In biosensing application, Ag-doped HA was reported to be potential applied for trace-level formaldehyde detection [ 9 ].…”
Section: Introductionmentioning
confidence: 99%