2022
DOI: 10.1016/j.jelechem.2022.116388
|View full text |Cite
|
Sign up to set email alerts
|

Simple and affordable graphene nano-platelets and carbon nanocomposite surface decorated with cetrimonium bromide as a highly responsive electrochemical sensor for rutin detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 52 publications
(14 citation statements)
references
References 33 publications
1
13
0
Order By: Relevance
“…A is the electrochemical surface area of the modified electrode and B is the slope of the calibration plot. The results given for the analytical parameters of RU at the modified surface of various electrodes are identical to the analytical parameters attained at the PGAMGPE, as shown in Table 1 [ 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 ]. Additionally, the PGAMGPE results validate that the PGAMGPE is an appropriate tool for the sensitive electrochemical detection of RU with a significant improvement in the simplified fabrication process.…”
Section: Resultssupporting
confidence: 58%
“…A is the electrochemical surface area of the modified electrode and B is the slope of the calibration plot. The results given for the analytical parameters of RU at the modified surface of various electrodes are identical to the analytical parameters attained at the PGAMGPE, as shown in Table 1 [ 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 ]. Additionally, the PGAMGPE results validate that the PGAMGPE is an appropriate tool for the sensitive electrochemical detection of RU with a significant improvement in the simplified fabrication process.…”
Section: Resultssupporting
confidence: 58%
“…This in turn increased the reactive sites and the mobility of electrons during the electrochemical studies at a 4 mg modifier concentration. We have also calculated the active surface area of the 4 mg HEA-MCPE and BCPE using the Randles-Sevcik equation [29][30][31][32][33][34] as below and the calculated diffusion coefficient of methylene blue for two-electron transfer redox reaction is found to be 5.30 × 10−6 cm 2 s -1 as per the literature [35]. The calculated active surface area for BCPE and HEA-MCPE is found to be 0.180 and 0.918 cm 2 respectively.…”
Section: Electro-oxidation Of Mb In Wastewater 331 Optimizing the Con...mentioning
confidence: 69%
“…The calculated values of LOD and LOQ are found to be 8.31 nM and 27.70 nM, respectively. The obtained LOD and the RT sensor are compared with the previous reports and the corresponding data are tabulated in Table 2 [28,32–46] . This comparison analysis shows that, the prepared sensor and used method provides acceptable LOD for the detection of RT.…”
Section: Resultsmentioning
confidence: 87%
“…Graphene is the allotrope of carbon and a monolayer of carbon atoms with hexagonal honeycomb lattice. Graphene has various significant features such as higher potential window, inexpensive, elevated electro‐active surface area, thermal conductivity, biocompatibility, chemical stability, electrical conductivity, and mechanical stability [28,40,46] . Because of these helpful features, in the present work we selected graphene as a vital base electrode material for RT analysis.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation