2017
DOI: 10.1016/j.sbsr.2016.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Simplified immunoassay for rapid Dengue serotype diagnosis, revealing insensitivity to non-specific binding interference

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“… Biosensor type Analyte Materials Real sample/spiked sample Detection range LOD Year Refs. Immunosensor NS1 Gold film electrode Serum 1–100 ng/mL 0.33 ng/mL 2012 42 LSPR fiber optic sensor NS1 Gold Nanoparticles 1.54 nM 2013 10 Immunosensor NS1 Microspheres Serum 5.2 ng/mL 2013 43 Impedimetric biosensor NS1 Gold electrode Neat serum 0.01–1.00 μg/mL 30 ng/mL 2015 44 SPR biosensors DENV2 Ag Gold film Serum 4 × 10 4 particles/mL 2017 45 FITC optical biosensors NS1 Indium tin oxide Plasma 15–500 ng/mL 15 ng/mL 2018 46 Immunosensor NS1 …”
Section: Resultsmentioning
confidence: 99%
“… Biosensor type Analyte Materials Real sample/spiked sample Detection range LOD Year Refs. Immunosensor NS1 Gold film electrode Serum 1–100 ng/mL 0.33 ng/mL 2012 42 LSPR fiber optic sensor NS1 Gold Nanoparticles 1.54 nM 2013 10 Immunosensor NS1 Microspheres Serum 5.2 ng/mL 2013 43 Impedimetric biosensor NS1 Gold electrode Neat serum 0.01–1.00 μg/mL 30 ng/mL 2015 44 SPR biosensors DENV2 Ag Gold film Serum 4 × 10 4 particles/mL 2017 45 FITC optical biosensors NS1 Indium tin oxide Plasma 15–500 ng/mL 15 ng/mL 2018 46 Immunosensor NS1 …”
Section: Resultsmentioning
confidence: 99%
“…The detection limit in samples spiked with nasal mucosa from flu-like syndrome patients was observed to be 402 copies/mL, which is significantly lower than the detection limit of conventional influenza detection approaches including rapid influenza diagnostic tests and quantitative reverse transcription-polymerase chain reaction (qRT-PCR). Similarly, Loureiro et al developed a PSPR-based immunoassay for the rapid diagnosis of dengue viral infection [49]. In this method, a neutravidin-biotin mediated monoclonal antibody is immobilized on a thin gold film as the sensing element.…”
Section: Analytical Methods For Viral Agentsmentioning
confidence: 99%
“…The diagnosis of dengue viral infection was possible by a rapid propagating surface plasmon resonance (PSPR)-based immunoassay, where a neutravidin-biotin monoclonal antibody (the sensing element) was immobilized on a thin gold film. An LoD of 2 × 10 4 particles/mL was obtained [ 64 ]. Avian influenza A H7N9 was detected by Chang et al [ 65 ].…”
Section: Surface Plasmon Resonance (Spr) Based Biosensorsmentioning
confidence: 99%