Medical Imaging 2019: Physics of Medical Imaging 2019
DOI: 10.1117/12.2511304
|View full text |Cite
|
Sign up to set email alerts
|

Simulation and experimental validation of high-resolution test objects for evaluating a next-generation digital breast tomosynthesis prototype

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 10 publications
(15 citation statements)
references
References 9 publications
0
15
0
Order By: Relevance
“…There are many possibly ways in which VCTs can be conducted. For example, we have conducted VCTs in which no machine observer is used; rather, we have used quantitative tools such as breast density 50 ; similarly, we have recently begun to use physics VCTs 24 in which quantitative measures such as phantom score 25 or spatial resolution 24 are evaluated. While physics VCTs were developed as a pass–fail step in moving a VCT‐designed imaging system into real clinical trials, they have proven to be useful in their own right.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are many possibly ways in which VCTs can be conducted. For example, we have conducted VCTs in which no machine observer is used; rather, we have used quantitative tools such as breast density 50 ; similarly, we have recently begun to use physics VCTs 24 in which quantitative measures such as phantom score 25 or spatial resolution 24 are evaluated. While physics VCTs were developed as a pass–fail step in moving a VCT‐designed imaging system into real clinical trials, they have proven to be useful in their own right.…”
Section: Discussionmentioning
confidence: 99%
“…Although there are many uses for VCTs, as a research group which develops imaging devices, we have primarily used VCTs to design and test novel devices and imaging algorithms. 5,[23][24][25][26] In our research, we first calibrate the VCT in terms of patient population, lesion admixture, and case difficulty to an existing study of a predicate device such that the VCT matches the existing clinical trial in terms of the study design and observed AUC. 1,5,14 We can then use this calibrated VCT dataset to evaluate a novel study device with the goal of demonstrating either equivalency or superiority to the predicate technology.…”
Section: Rationalementioning
confidence: 99%
“…One of the earliest applications of VCTs was in the area of breast imaging for investigations of image quality, dosimetry, optimization, and technology evaluation. 30,213,[278][279][280][281][282][283][284][285][286][287][288][289] Recent VCTs have attempted to predict the ranking and the magnitude of improvement of breast imaging technologies as seen by human observers. 26,278,[290][291][292] In one example, VCTs were used in the Optimam project to evaluate the smallest detectable diameter of various lesions, showing that digital breast tomosynthesis (DBT) is superior to digital mammography (DM) for masses, 290 while the converse is true for calcifications.…”
Section: Breast Imagingmentioning
confidence: 99%
“…One of the earliest applications of VCTs was in the area of breast imaging for investigations of image quality, dosimetry, optimization, and technology evaluation. 30 , 213 , 278 289 Recent VCTs have attempted to predict the ranking and the magnitude of improvement of breast imaging technologies as seen by human observers. 26 , 278 , 290 292 …”
Section: Vct Applicationsmentioning
confidence: 99%
See 1 more Smart Citation