2015
DOI: 10.1016/j.ijrefrig.2015.04.018
|View full text |Cite
|
Sign up to set email alerts
|

Simulation based identification of the ideal defrost start time for a heat pump system for electric vehicles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…Ahn et al also studied effective dehumidification by a heat pump with a dual-evaporator system in electric vehicles [109]. A research study by Steiner and Rieberer concluded that incorrectly chosen defrost starting time reduced the efficiency of the heat pump system significantly [110].…”
Section: State-of-the-art Technologies For Cabin Thermal Managementmentioning
confidence: 99%
See 2 more Smart Citations
“…Ahn et al also studied effective dehumidification by a heat pump with a dual-evaporator system in electric vehicles [109]. A research study by Steiner and Rieberer concluded that incorrectly chosen defrost starting time reduced the efficiency of the heat pump system significantly [110].…”
Section: State-of-the-art Technologies For Cabin Thermal Managementmentioning
confidence: 99%
“…Their research focused on improving the efficiency of a heat pump by recovering heat from the fuel cell stack exhaust with different heat exchanger arrangements. Steiner and Rieberer developed a transient model of a reversible heat pump system with CO2 refrigerant aiming at analyzing the influence of defrosting start time [110].…”
Section: State-of-the-art Technologies For Cabin Thermal Managementmentioning
confidence: 99%
See 1 more Smart Citation
“…Microfiber heating blankets, graphene-based heating bedding, and flexible flat heating elements based on stainless steel metal fiber electrodes are commercially available, and the application range of this technology continues to expand. However, warm clothing with full thermostatic properties at specific temperatures has not yet been reported [ 21 , 22 , 23 , 24 , 25 , 26 ]. A heating element without PTC characteristics relies on a thermostat or electronic circuit to control the applied power, but these components can be associated with discomfort during wearing or activity, performance degradation after washing, and burn or fire risks due to abnormal heat generation.…”
Section: Introductionmentioning
confidence: 99%
“…14 of the 19 tests developed in cooling mode. Only the testing conditions with condenser air supply temperature higher than 35ºC are considered in this table.…”
mentioning
confidence: 99%