2019
DOI: 10.1016/j.energy.2019.02.127
|View full text |Cite
|
Sign up to set email alerts
|

Simulation of rapid increase in the steam mass flow rate at a supercritical power boiler outlet

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(6 citation statements)
references
References 18 publications
0
6
0
Order By: Relevance
“…The configuration option was fit for power-up regulation. A pressure drop with relevant fuel input increase option for rapid load rise was presented in [75]. A supercritical coal-fired power plant was modeled with an in-house developed code, to simulate a fast load change of 5%/30 s as a power-grid requirement.…”
Section: Ramping Ratementioning
confidence: 99%
See 1 more Smart Citation
“…The configuration option was fit for power-up regulation. A pressure drop with relevant fuel input increase option for rapid load rise was presented in [75]. A supercritical coal-fired power plant was modeled with an in-house developed code, to simulate a fast load change of 5%/30 s as a power-grid requirement.…”
Section: Ramping Ratementioning
confidence: 99%
“…During those, steady-state and transient data were collected. The simulations incorporated a quartet of ramping rates-2, 4, 8 and 16%/min-a 10%-load step change, and a A pressure drop with relevant fuel input increase option for rapid load rise was presented in [75]. A supercritical coal-fired power plant was modeled with an in-house developed code, to simulate a fast load change of 5%/30 s as a power-grid requirement.…”
Section: Ramping Ratementioning
confidence: 99%
“…The effect of different parameters of the emergency supply pump on the safety of the heating surfaces was carefully investigated; however, in the model, the heat fluxes to the heating surfaces were simply derived from experimental data, making it difficult to be applied to other boilers despite having similar structures. Other studies have also been conducted on the transient process in supercritical boilers [12][13][14][15][16][17][18][19][20]; however, they are of little referential significance.…”
Section: Introductionmentioning
confidence: 99%
“…The decline in the pressure reasons to a small portion of the saturated water in the boiler immediately vaporizes; this produces a large magnitude of boil-up from most of the boiler tubes. So that, the level controller sensing an elevation in the level of the pressure cycles of the drum will be caused variation in drum level [5].…”
Section: Introductionmentioning
confidence: 99%