2023
DOI: 10.1088/1402-4896/acb023
|View full text |Cite
|
Sign up to set email alerts
|

Simulation study of reconfigurable surface plasmon resonance refractive index sensor employing bismuth telluride and MXene nanomaterial for cancer cell detection

Abstract: In this study, a highly angular sensitive surface plasmon resonance (SPR) biosensor has been designed for cancer cell detection. The proposed surface plasmon resonance biosensor structure is based on Kretschmann configuration, which works on an angular interrogation technique. The proposed SPR biosensor has enormous possibility to detect the various kind of cancer cells. The refractive index alteration of different cancerous (skin, cervical and blood) cells is 1.360-1.390. The proposed SPR biosensor is stacked… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(6 citation statements)
references
References 41 publications
0
6
0
Order By: Relevance
“…Detection Accuracy (DA) parameter calculates the sensor's exactness. Numerically expressed by [28]: DA = ๐น๐‘Š๐ป๐‘€ โˆ’1 , expressed in Deg โˆ’1 , Another parameter that calculates the quality of the sensor is the Figure of merit (FOM) or Quality factor (Q). Mathematically expressed by [29]: ๐น๐‘‚๐‘€ = ๐‘† .…”
Section: Methodology and Considerationsmentioning
confidence: 99%
“…Detection Accuracy (DA) parameter calculates the sensor's exactness. Numerically expressed by [28]: DA = ๐น๐‘Š๐ป๐‘€ โˆ’1 , expressed in Deg โˆ’1 , Another parameter that calculates the quality of the sensor is the Figure of merit (FOM) or Quality factor (Q). Mathematically expressed by [29]: ๐น๐‘‚๐‘€ = ๐‘† .…”
Section: Methodology and Considerationsmentioning
confidence: 99%
“…The detection accuracy (DA) parameter calculates the sensorโ€™s exactness. Numerically expressed by [ 29 ]: (expressed in ). Another parameter that calculates the quality of the sensor is the figure of merit (FOM) or quality factor (Q).…”
Section: Methodology and Considerationsmentioning
confidence: 99%
“…Singh et al conducted a simulation study to analyze the SPR sensor and optimized the design using reconfigurable surfaces. 29 The best results of different cancer cells in the assay were analyzed and important performance parameters such as sensitivity and detection accuracy were obtained. This model helps to improve the design efficiency of SPR biosensors and further optimize the performance.…”
Section: Introductionmentioning
confidence: 99%