2021
DOI: 10.1016/j.bios.2021.113288
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous and sensitive determination of Escherichia coli O157:H7 and Salmonella Typhimurium using evanescent wave dual-color fluorescence aptasensor based on micro/nano size effect

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(23 citation statements)
references
References 25 publications
0
23
0
Order By: Relevance
“…In addition, a study aimed at the development of a fluorescent biosensor for the detection of two common bacteria, E. coli O157:H7 and Salmonella Typhimurium [24] . The fabrication of this biosensor did not require the complex immobilization of biorecognition elements on the sensor surface.…”
Section: Biosensors For the Detection Of Pathogensmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, a study aimed at the development of a fluorescent biosensor for the detection of two common bacteria, E. coli O157:H7 and Salmonella Typhimurium [24] . The fabrication of this biosensor did not require the complex immobilization of biorecognition elements on the sensor surface.…”
Section: Biosensors For the Detection Of Pathogensmentioning
confidence: 99%
“…This enrichment step was crucial to increase the bacterial count and meet the LOD of rapid tests, which was in the range of 10 3 –10 5 CFU/mL for Salmonella . Biosensors, on the other hand, provide much higher sensitivities, with the most recent LODs being in the range of 10–10 2 CFU/mL [24] , [21] .…”
Section: Biosensors For the Detection Of Pathogensmentioning
confidence: 99%
“…6a). The S. typhimurium concentration in the samples below 1 × 10 2 CFU/mL is considered safe because the infectious dose for S. typhimurium is 1 × 10 3 CFU/mL [34].…”
Section: Sensitivity and Selectivity Of The Aptasensormentioning
confidence: 99%
“…Fluorescence analysis is one of the optical sensing methods to quantify the concentration of the target according to the fluorescence intensity of the labeled materials, which can solve the color interference of a food matrix when using colorimetric methods. The generated fluorescence signal can be visually observed by a fluorescence observer or measured by a fluorescence spectrometer [83,84]. Fluorescence analysis has two main means of fluorescence generation; one mean is the direct measurement of the fluorescence intensity from fluorescent materials; the other mean is the indirect measurement of fluorescence quenching to reflect the amount of Salmonella.…”
Section: Fluorescence Analysismentioning
confidence: 99%