2005
DOI: 10.2116/analsci.21.15
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Chiral Analysis of Methamphetamine and Related Compounds by Capillary Electrophoresis/Mass Spectrometry Using Anionic Cyclodextrin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
40
0

Year Published

2005
2005
2018
2018

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 48 publications
(41 citation statements)
references
References 16 publications
1
40
0
Order By: Relevance
“…The different strategies used to avoid the entrance of the chiral selector into the mass analyzer, preventing a deterioration of the sensitivity, were the partial filling of the capillary with the separation media containing the chiral selector in combination with anionic CDs migrating in countercurrent [21,22] or the use of anionic CDs migrating in countercurrent with suppressed EOF [43]. Table 3 reveals that LODs reached in works using EKC-ESI-MS were comprised from 3610 25 to 4610 29 M. Rudaz et al used the countercurrent migration of the negatively charged highly sulfated-g-CD (HS-g-CD) and the partial-filling technique to achieve the enantioseparation of amphetamine derivatives [21,22].…”
Section: End-column Detection In Chiral Analysis By Cementioning
confidence: 99%
See 1 more Smart Citation
“…The different strategies used to avoid the entrance of the chiral selector into the mass analyzer, preventing a deterioration of the sensitivity, were the partial filling of the capillary with the separation media containing the chiral selector in combination with anionic CDs migrating in countercurrent [21,22] or the use of anionic CDs migrating in countercurrent with suppressed EOF [43]. Table 3 reveals that LODs reached in works using EKC-ESI-MS were comprised from 3610 25 to 4610 29 M. Rudaz et al used the countercurrent migration of the negatively charged highly sulfated-g-CD (HS-g-CD) and the partial-filling technique to achieve the enantioseparation of amphetamine derivatives [21,22].…”
Section: End-column Detection In Chiral Analysis By Cementioning
confidence: 99%
“…The use of another anionic CD, the heptakis(2,6-diacethyl-6-sulfato)-b-CD (DAS-b-CD), which moves to the inlet of the capillary and does not flow into the MS detector was used in a selective EKC-ESI-MS method for the simultaneous chiral separation of six drugs [43]. In this work, the EOF was also suppressed by adjusting the pH value of the electrolyte to less than 3.…”
Section: End-column Detection In Chiral Analysis By Cementioning
confidence: 99%
“…Thus, two different derivatization protocols for amino acids using dansyl chloride (DNS) and FITC were compared observing better mass sensitivity for FITC-amino acids (LODs in the mM range) [139]. CE-ESI-MS has also been used for the sensitive determination of chiral compounds in biological samples such as urine [135,140,141], plasma [142], serum [143], and in vivo samples [144], and for the identification of drugs and their metabolites [145,140].…”
Section: Alternative Detection Systems To On-column Uv-vis Absorptionmentioning
confidence: 99%
“…Recently, we have reported highly sensitive methods for MA and its metabolites by CE/MS. 26,27) However, these methods require a procedure of extraction from urine. Therefore, the purpose of this study was to develop a rapid, simple and highly sensitive CE/MS with direct injection of urine for quantifying chiral analysis of seven methamphetamine-related compounds.…”
Section: Introductionmentioning
confidence: 99%