2009
DOI: 10.1021/jf9024773
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of Cd and Fe in Beans and Soil of Different Regions of Brazil Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry and Direct Solid Sampling

Abstract: A fast routine screening method for the simultaneous determination of cadmium and iron in bean and soil samples is proposed, using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling. The primary absorption line at 228.802 nm has been used for the determination of cadmium, and an adjacent secondary line, at 228.726 nm, for iron. Fourteen bean samples and 10 soil samples from nine states all over Brazil have been analyzed. The limits of detection (3 sigma, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 41 publications
(23 citation statements)
references
References 20 publications
0
23
0
Order By: Relevance
“…The original idea of this work has been to transfer the procedure that has been developed for the simultaneous determination of Cd and Fe in grain products using direct solid sampling [9] to the analysis of bean and soil samples from different regions of Brazil [7]. While the procedure worked well for the bean samples, the soil samples turned out to be a problem due to their extremely high iron content.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The original idea of this work has been to transfer the procedure that has been developed for the simultaneous determination of Cd and Fe in grain products using direct solid sampling [9] to the analysis of bean and soil samples from different regions of Brazil [7]. While the procedure worked well for the bean samples, the soil samples turned out to be a problem due to their extremely high iron content.…”
Section: Resultsmentioning
confidence: 99%
“…In order to coat the platform with the W-Ir mixed permanent modifier, five aliquots of 40 µL of the W modifier solution were applied first, each one followed by the temperature program shown in Ref. [7,9], then five aliquots of 40 µL of the Ir modifier solution were applied, also followed by the same temperature program, resulting in a coating with 200 µg each of W and Ir.…”
Section: Reagents and Standardsmentioning
confidence: 99%
See 2 more Smart Citations
“…Therefore, there is a growing interest in developing reliable sensitive quantitative methodologies for the determination of the amount of micro minerals in various real samples. The most common methods for the determination of Zn 2+ , Fe 2+ , Co 2+ and Cu 2+ simultaneously or in combination with other micro minerals in pharmaceutical product and various vegetable samples are flame atomic absorption spectroscopy (FAAS) [8,9], graphite furnace atomic absorption spectrometry (GF-AAS) [10], inductively coupled plasma-mass spectrometry (ICP-MS) [11,12], inductively coupled plasma-atomic emission spectrometry (ICP-AES) [13,14], electrochemical methods [15][16] and ion chromatography [17]. However, some of the aforementioned methods employ expensive instruments and/or material, high purity solvents and often pretreatment steps of samples are required.…”
Section: Introductionmentioning
confidence: 99%