2015
DOI: 10.1016/j.electacta.2014.12.087
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of Copper, Lead, and Cadmium Ions at a Mo 6 S 9-x I x Nanowires Modified Glassy Carbon Electrode Using Differential Pulse Anodic Stripping Voltammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
13
2
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(18 citation statements)
references
References 36 publications
2
13
2
1
Order By: Relevance
“…The data reveals that CNT/nanoAu-SiO 2 is highly sensitive, enabling detection of lower Cu 2+ and Pb 2+ concentrations compared to all other electrodes tested here. Compared with the recent literature, our electrode was better than Mo6SxI9-x NWs/GCE [27, 28] not only for copper but also for lead, with LOD and LOQ values for the CNT/nanoAu-SiO 2 electrode lower than those for the Mo6SxI9-x NWs/GCE electrode.…”
Section: Resultscontrasting
confidence: 49%
“…The data reveals that CNT/nanoAu-SiO 2 is highly sensitive, enabling detection of lower Cu 2+ and Pb 2+ concentrations compared to all other electrodes tested here. Compared with the recent literature, our electrode was better than Mo6SxI9-x NWs/GCE [27, 28] not only for copper but also for lead, with LOD and LOQ values for the CNT/nanoAu-SiO 2 electrode lower than those for the Mo6SxI9-x NWs/GCE electrode.…”
Section: Resultscontrasting
confidence: 49%
“…[45], Table 2; ref. [47], Table 1), the LOD obtained in our work was lower. Some polymer brush or polymer composites on substrate for determination of Pb 2+ ion were also compared with our work and shown in Table 1.…”
Section: Detection Of Pb 2+ Ioncontrasting
confidence: 54%
“…10c. At shorter preconcentration time, the peak currents for Pb 2+ ion increased with the deposition time, owing to the increased amount of metal ions on the PAM/Au electrode [45,47]. It reached a large data at 240 s, suggesting a saturation of metal.…”
Section: Detection Of Pb 2+ Ionmentioning
confidence: 93%
“…They have received considerable intention of the scientist due to their venomous effects in human beings, and other living organisms even at trace levels [1][2][3][4][5][6]. Due to noxious effects of these heavy metals like kidney failure, liver damage, cancer, nausea central nervous system, high blood pressure, pulmonary fibrosis, skin dermatitis, renal edema, diarrhea and vomiting, spectroscopic methods for determination of trace and ultratrace level of these metals in water, food and biological samples have become of challenging research area for analytical chemists [1,[7][8][9][10][11]. Due to low level of these heavy metals in environmental samples than the detection limits of the spectroscopic methods, the direct determination of these trace metals is generally not possible.…”
Section: Introductionmentioning
confidence: 99%