Simultaneous determination of four different antibiotic residues in honey by chemiluminescence multianalyte chip immunoassays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
35
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 67 publications
(35 citation statements)
references
References 37 publications
0
35
0
Order By: Relevance
“…For this reason, it has been also extensively employed in microfluidic devices, providing superior analytical performance with respect to other optical detection techniques. 6,7 However, in most cases, off-chip detection devices, such as cooled CCDs or photomultipler tubes have been used to detect the emitted light, thus partially compromising the integration level of the device.…”
Section: Chemiluminescence Analytical Chemistrymentioning
confidence: 99%
“…For this reason, it has been also extensively employed in microfluidic devices, providing superior analytical performance with respect to other optical detection techniques. 6,7 However, in most cases, off-chip detection devices, such as cooled CCDs or photomultipler tubes have been used to detect the emitted light, thus partially compromising the integration level of the device.…”
Section: Chemiluminescence Analytical Chemistrymentioning
confidence: 99%
“…Therefore, the extraction material (Chromabond 1 Easy) was obtained from Macherey-Nagel (D€ uren, Germany) and was dry packed in a stainless steel column cartridge (30 Â 4.6 mm id). This material is a polar, bifunctionally modified PS/DVB copolymer with a weak anion exchanger, (specific surface 650-700 m 2 g À1 , particle size 80 mm, pore size 50 Å, pH stability [1][2][3][4][5][6][7][8][9][10][11][12][13][14]. Before packing, the empty cartridge was cleaned in an ultrasonic methanol bath.…”
Section: Columnsmentioning
confidence: 99%
“…Several methods [12][13][14] have been used for the determination of SDZ in a variety of matrices, most of which are based on liquid chromatography [15][16][17][18][19][20][21]. Most of these methods used in biological matrices such as blood and tissues require solid phase extraction (SPE) and several sample preparation processes, like filtration, deproteinisation, extraction, centrifugation and concentration [22].…”
Section: Introductionmentioning
confidence: 99%
“…There are very few studies that effectively employ this promising technology for the detection of antibiotics. An immunoassay using the microarray chip reader 3 platform has been described for the determination of antibiotic residues in milk (Kloth et al, 2009a;2009b) and honey (Wutz et al 2011). A novel multiplex nanoarray based on planar waveguide with fluorescence detection was developed for the detection of a number of antibiotics including CAP (McGrath et al, 2015) in milk.…”
Section: Introductionmentioning