2018
DOI: 10.3390/pharmaceutics10020041
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of Procainamide and N-acetylprocainamide in Rat Plasma by Ultra-High-Pressure Liquid Chromatography Coupled with a Diode Array Detector and Its Application to a Pharmacokinetic Study in Rats

Abstract: A simple, sensitive, and reliable reversed-phase, Ultra-High-Pressure Liquid Chromatography (UHPLC) coupled with a Diode Array Detector (DAD) method for the simultaneous determination of Procainamide (PA) and its major metabolite, N-acetylprocainamide (NAPA), in rat plasma was developed and validated. A simple deproteinization method with methanol was applied to the rat plasma samples, which were analyzed using UHPLC equipped with DAD at 280 nm, and a Synergi™ 4 µm polar, reversed-phase column using 1% acetic … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 29 publications
0
8
0
Order By: Relevance
“…The concentrations of PA and NAPA in various matrices (e.g., plasma, urinary samples, and samples from in vitro studies) were determined as previously described [36]. Briefly, analyses were performed with an Agilent Technologies 1290 Infinity II UHPLC system (Agilent Technologies, Palo Alto, CA, USA) equipped with a multisampler (G7167B), a flexible pump (G7104A), a multicolumn thermostat (MCT) (G7116B), and a DAD detector (G7117A).…”
Section: Methodsmentioning
confidence: 99%
“…The concentrations of PA and NAPA in various matrices (e.g., plasma, urinary samples, and samples from in vitro studies) were determined as previously described [36]. Briefly, analyses were performed with an Agilent Technologies 1290 Infinity II UHPLC system (Agilent Technologies, Palo Alto, CA, USA) equipped with a multisampler (G7167B), a flexible pump (G7104A), a multicolumn thermostat (MCT) (G7116B), and a DAD detector (G7117A).…”
Section: Methodsmentioning
confidence: 99%
“…ESI positive and negative modes were both compared and evaluated in method development [24,25,26]. In this work, the response of the positive ion mode showed a better signal-to-noise ratio than that of the negative ion mode.…”
Section: Resultsmentioning
confidence: 99%
“…Experimental animal protocols were reviewed and approved by the Animal Care and Use Committee of the Gachon University (#GIACUC-R2018022, approval date 7 November 2018). As described in our recent pharmacokinetic study [26], overnight fasted rats were anesthetized intramuscularly with Zoletil (20 mg/kg), and a femoral vein and artery were then surgically cannulated with polyethylene tubing (PE50; Clay Adams, Parsippany, NJ, USA). The cannula was flushed with 20 IU/mL heparinized saline to prevent clotting.…”
Section: Methodsmentioning
confidence: 99%