2008
DOI: 10.1016/j.talanta.2008.01.053
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of Pt and Rh by catalytic adsorptive stripping voltammetry, using hexamethylene tetramine (HMTA) as complexing agent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
11
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 21 publications
2
11
0
Order By: Relevance
“…4C at the GC/Bi-AgFE nanosensor shown linear response with linear calibration equation y = 0.708x À 0.0434 and y = 0.222x + 0.0282 for Pd(HDMG) 2 and Rh(HDMG) 3 , respectively. These results obtained for the simultaneous determination of Pd(II) and Rh(III) complexes were compared with results obtained by other researchers [5,6,10,11]. In comparison with the work done by Van der Horst et al [10] and Silwana et al [11], better defined peaks were observed for Pd-Rh complexes in this presented study with lower detection limits.…”
Section: Stripping Voltammetric Analysis Of Pgmssupporting
confidence: 78%
See 3 more Smart Citations
“…4C at the GC/Bi-AgFE nanosensor shown linear response with linear calibration equation y = 0.708x À 0.0434 and y = 0.222x + 0.0282 for Pd(HDMG) 2 and Rh(HDMG) 3 , respectively. These results obtained for the simultaneous determination of Pd(II) and Rh(III) complexes were compared with results obtained by other researchers [5,6,10,11]. In comparison with the work done by Van der Horst et al [10] and Silwana et al [11], better defined peaks were observed for Pd-Rh complexes in this presented study with lower detection limits.…”
Section: Stripping Voltammetric Analysis Of Pgmssupporting
confidence: 78%
“…This observation is an indication that the sensor is more favourable for Pd(II) and Pt(II) studies. The results obtained for the simultaneous determination of Pt(II) and Rh(III) complexes were compared with results obtained by Dalvi et al [5]. The work done by Dalvi et al [5] showed better defined peaks and with better detection limits for the Pt-Rh complexes as in the present study.…”
Section: Stripping Voltammetric Analysis Of Pgmssupporting
confidence: 67%
See 2 more Smart Citations
“…Close reduction peak potentials and severe matrix effects limit direct application of AV for simultaneous detection of PGMs. Optimizing the electrolyte composition can allow simultaneous detection of Pt, Pd, and Rh [101] and of Pt and Rh [102]. AV is extremely sensitive to organic matrices.…”
Section: Instrumental Techniques For the Detection Of Pgmsmentioning
confidence: 99%