2007
DOI: 10.1016/j.chroma.2006.10.037
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of the endocrine disrupting compounds nonylphenol, nonylphenol ethoxylates, triclosan and bisphenol A in wastewater and sewage sludge by gas chromatography–mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

14
142
1
15

Year Published

2008
2008
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 300 publications
(172 citation statements)
references
References 41 publications
14
142
1
15
Order By: Relevance
“…3, ranged from 60 to 140%. These results were comparable with those reported by other researchers (Cathum and Sabik, 2001;Cai et al, 2003;Hoai et al, 2003;Gatidou et al, 2007;Dirtu et al, 2008). The obtained recovery results were considered to be satisfactory, considering that different types of analytes with different chemical structure and polarities were extracted simultaneously.…”
Section: Recovery Of Targeted Analytes From Simulated Water Samplessupporting
confidence: 81%
See 1 more Smart Citation
“…3, ranged from 60 to 140%. These results were comparable with those reported by other researchers (Cathum and Sabik, 2001;Cai et al, 2003;Hoai et al, 2003;Gatidou et al, 2007;Dirtu et al, 2008). The obtained recovery results were considered to be satisfactory, considering that different types of analytes with different chemical structure and polarities were extracted simultaneously.…”
Section: Recovery Of Targeted Analytes From Simulated Water Samplessupporting
confidence: 81%
“…From the results in Table 1, BSTFA yielded a fast derivatization reaction as the reaction was complete within 20 min, but this was obtained at a higher temperature (65°C) (Gatidou et al, 2007). Another study by Fiedler et al (2007) also used BSTFA but the reaction took place at room temperature for 2 h. These 2 studies indicated the effect of temperature on derivatization with BSTFA as the derivatization was quicker at an elevated temperature than at room temperature.…”
Section: Comparison Of the Derivatization Protocol With Other Reportementioning
confidence: 91%
“…BPA , . , (Rudel et al, 1998;Heemken et al, 2001;Helaleh et al, 2001;Kuch and Ballschmiter, 2001;Li et al, 2001;Kawaguchi et al, 2006 (Gatidou et al ., 2007).…”
Section: Bpamentioning
confidence: 99%
“…A number of analytical methods such as high-performance liquid chromatography (HPLC), 3 liquid chromatography coupled with mass spectrometry (LC-MS), 4 gas chromatography− mass spectrometry (GC-MS), 5 fluorescence detection method, 6 flow injection inhibitory chemiluminescence method, 7 and enzyme-linked immunosorbent assay 8 have been reported for the detection of BPA. These methods are quite sensitive, but they are very complicated and require sophisticated instruments.…”
Section: Introductionmentioning
confidence: 99%