2017
DOI: 10.1016/j.jcis.2016.11.006
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of trace Cd(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetry using a reduced graphene oxide-chitosan/poly-l-lysine nanocomposite modified glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
65
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 187 publications
(66 citation statements)
references
References 58 publications
1
65
0
Order By: Relevance
“…A reduction peak was observed at −0.50 V in the reverse cathodic scan (Figure A). Quite similar voltammograms for PLL were appeared in the literature . The peak currents increased in magnitude with the scanning cycles relatively large at initial cycles slowing down with increasing number of cycles.…”
Section: Resultssupporting
confidence: 77%
See 2 more Smart Citations
“…A reduction peak was observed at −0.50 V in the reverse cathodic scan (Figure A). Quite similar voltammograms for PLL were appeared in the literature . The peak currents increased in magnitude with the scanning cycles relatively large at initial cycles slowing down with increasing number of cycles.…”
Section: Resultssupporting
confidence: 77%
“…Moreover, the sensitivity of the Ty/Fe 3 O 4 −CH/PLL/SPCE was found to be higher than the previously reported tyramine biosensors based on titania sol‐gel modified with mesoporous carbon and polycationic polymer poly(diallyldimethylammonium chloride (486 μAmM −1 cm −2 ) . Ty/Fe 3 O 4 −CH/PLL/SPCE responded rapidly to changes in tyramine concentration and reached 95 % of the steady‐state current in less than 10 s. This low response time can be attributed to the hydrogen bonds between CH and PLL and the accelerated electron transfer rate by the movement of electrons through these hydrogen bonds .…”
Section: Resultsmentioning
confidence: 66%
See 1 more Smart Citation
“…Because of a concern on the environment the widespreadly utilized hanging mercury drop and mercury film electrodes were replaced by gold , modified carbon paste or other carbon materials electrodes , electrodes modified with metals more eco‐friendly than mercury on various substrates and array of iridium microdisks for determination of copper traces. In view of the fact that preparation of chemically modified electrodes is usually time‐consuming process, simple electrochemical modification of various substrates with metal films seems to be a convenient alternative.…”
Section: Introductionmentioning
confidence: 99%
“…Due to serious hazardous effects of heavy metal ions on human health and toxicity in the environment [7], it is important to develop a simple and highly effective removal method as well as sensitive analytical method for environmental pollutants to improve the quality of the environment and the human life.…”
Section: Introductionmentioning
confidence: 99%