2022
DOI: 10.1007/s00604-022-05201-z
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous electrochemical detection of gallic acid and uric acid with p-tert-butylcalix[4]arene-based coordination polymer/mesoporous carbon composite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 40 publications
0
6
0
Order By: Relevance
“…In addition, their selfassembled pore structures can accelerate the adsorption response toward HMIs, which is beneficial for the preconcentration process of HMIs. 41,42 For instance, Wang et al…”
Section: ■ Introductionmentioning
confidence: 99%
“…In addition, their selfassembled pore structures can accelerate the adsorption response toward HMIs, which is beneficial for the preconcentration process of HMIs. 41,42 For instance, Wang et al…”
Section: ■ Introductionmentioning
confidence: 99%
“…Since GA possesses anti-mutagenic, antibacterial and antiaging properties, [1][2][3] and has a favorable preventive effect on several diseases, it has attracted increasing attention for application in food, cosmetics, medicines, etc. 4,5 Unfortunately, excessive intake of GA is harmful to the human body, leading to various diseases, such as dizziness, fatigue, headache, and stomach upset. 6,7 Therefore, developing a rapid and efficient detection method for GA is critical.…”
Section: Introductionmentioning
confidence: 99%
“…13,14 However, many of these procedures may necessitate elaborate pretreatments or take an excessive amount of time. 15 Because of its unusual electrochemical activity, UA may be permanently oxidized into active ingredients in an aqueous solution. Many studies have focused on quantifying UA using electrochemical approaches, recognized as viable alternatives to older approaches.…”
Section: ■ Introductionmentioning
confidence: 99%
“…When combined with a 4-aminoantipyrine–peroxidase system, the uricase test is one of the most effective enzymatic determinations of UA. Evaluating the UA concentrations in human bodily fluids is thus clinically beneficial and important for prevention of the previously described disorders or even other comparable disorders. Furthermore, UA concentration monitoring in human bodily fluids is critical; different detection methods, which include enzyme detection, high-performance liquid chromatography (HPLC), UV detection, mass spectrometry, colorimetry, and electrochemical sensors, have been developed in response to earlier studies. , However, many of these procedures may necessitate elaborate pretreatments or take an excessive amount of time . Because of its unusual electrochemical activity, UA may be permanently oxidized into active ingredients in an aqueous solution.…”
Section: Introductionmentioning
confidence: 99%