2017
DOI: 10.1021/acs.analchem.7b01690
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Electrochemical Speciation of Oxidized and Reduced Glutathione. Redox Profiling of Oxidative Stress in Biological Fluids with a Modified Carbon Electrode

Abstract: The simultaneous electrochemical quantification of oxidized (GSSG) and reduced glutathione (GSH), biomarkers of oxidative stress, is demonstrated in biological fluids. The detection was accomplished by the development of a modified carbon electrode and was applied to the analysis of biological fluids of model organisms under oxidative stress caused by lead intoxication. Nanocomposite molecular material based on cobalt phthalocyanine (CoPc) and multiwalled carbon nanotubes functionalized with carboxyl groups (M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(10 citation statements)
references
References 65 publications
0
10
0
Order By: Relevance
“…S12 † ). The current responses caused by H 2 O 2 oxidation increased with the increase of CoPc contents and reached a peak at a level of 20 mM, and the declining response at a concentration of 25 mM or even higher probably resulted from the formation of CoPc precipitates 45 with low electrocatalytic efficiency towards H 2 O 2 oxidization.…”
Section: Resultsmentioning
confidence: 98%
“…S12 † ). The current responses caused by H 2 O 2 oxidation increased with the increase of CoPc contents and reached a peak at a level of 20 mM, and the declining response at a concentration of 25 mM or even higher probably resulted from the formation of CoPc precipitates 45 with low electrocatalytic efficiency towards H 2 O 2 oxidization.…”
Section: Resultsmentioning
confidence: 98%
“…Besides, GSH is easily oxidized under normal conditions, , requiring laborious and time-consuming sample processing. The most widely used approaches involve a previous sample derivatization with, for example, N -ethylmaleimide followed by acidic protein precipitation ,,,,, and a chromatographic or electrophoretic separation with different detectors. , Alternative approaches based on enzymatic assays or electrochemical determinations have also been reported. However, none of them enables a direct analysis of GSH, and they suffer from relevant limitations for their application in neonatal intensive care units such as the use of relatively large sample volumes (typically tens to hundreds of microliters of whole blood); time required for sample collection, pretreatment, and analysis; the use of expensive equipment and reagents; and the need of experienced personnel.…”
mentioning
confidence: 99%
“…A composite of cobalt phthalocyanine and functionalized multiwalled carbon nanotubes was fabricated for detection of glutathione. The LOD value was found to be 100 μM and 8.3 μM for reduced glutathione and oxidized glutathione respectively . Several sensing platforms for electrochemical detection of glutathione are compiled in Table .…”
Section: D Layered Materials Based (Bio)sensors For Oxidative Stress ...mentioning
confidence: 99%