2014
DOI: 10.1016/j.trac.2014.07.015
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous separation of cations and anions in capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 39 publications
(28 citation statements)
references
References 55 publications
0
28
0
Order By: Relevance
“…Since the capacitively coupled contactless conductive detector (C 4 D) was proposed by Zemann et al [5] and da Silva and do Lago [6] in 1998, capillary electrophoresis (CE) and microchip electrophoresis (ME) methods have been applied extensively in the determination of ionic species [7][8][9][10][11][12]. For the CE-C 4 D, many different techniques for concurrent separations have been discussed in a recent review [13]. Wuersig et al reported a simultaneous determination method in short fused silica capillary, the analysis of cations and anions could be carried out by switching the polarity of the high voltage supply.…”
Section: Introductionmentioning
confidence: 99%
“…Since the capacitively coupled contactless conductive detector (C 4 D) was proposed by Zemann et al [5] and da Silva and do Lago [6] in 1998, capillary electrophoresis (CE) and microchip electrophoresis (ME) methods have been applied extensively in the determination of ionic species [7][8][9][10][11][12]. For the CE-C 4 D, many different techniques for concurrent separations have been discussed in a recent review [13]. Wuersig et al reported a simultaneous determination method in short fused silica capillary, the analysis of cations and anions could be carried out by switching the polarity of the high voltage supply.…”
Section: Introductionmentioning
confidence: 99%
“…This is to give time for the operator to calculate the time interval ∆t = bτ/L d that needs to be inserted into the programming of the high voltage distributor before the group of bands reaches the midpoint at x = b/ 2, which is the instant of the first rotation. Simultaneous analysis of cations and anions is very desirable in many applications . The simultaneous electrokinetic injection of a sample in reservoirs 1 and 3 allows the concurrent analysis of cations and anions in the scheme of Fig.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, CE showed high suitability for the simultaneous determination of a drug compound and its counter‐ion in a single run. This can easily be achieved in case of cations and slow migrating anions by simply increasing the EOF to force both anions and cations to migrate in the same direction to reach the detector .…”
Section: Separation and Analysis Of Small Moleculesmentioning
confidence: 99%