2013
DOI: 10.1111/j.1525-1403.2012.00503.x
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Thalamic and Posterior Subthalamic Electrode Insertion With Single Deep Brain Stimulation Electrode for Essential Tremor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0
3

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(24 citation statements)
references
References 34 publications
1
20
0
3
Order By: Relevance
“…TETRAS performance scores correlated well with transducer measures of tremor and with the TETRAS ADL subscale . Good test‐retest reliability and sensitivity to change have been demonstrated for upper limb postural and kinetic ET …”
Section: Resultsmentioning
confidence: 78%
“…TETRAS performance scores correlated well with transducer measures of tremor and with the TETRAS ADL subscale . Good test‐retest reliability and sensitivity to change have been demonstrated for upper limb postural and kinetic ET …”
Section: Resultsmentioning
confidence: 78%
“…So far, sensitivity to change of a clinical scale has only been shown for the daily variation of ET in upper limb tremor 4 and in a case series of five patients after DBS 5 . Our results systematically show that a change of ET after intake of a standardized amount of ethanol is captured equally well by the TETRAS Performance scale, used clinically, as by accelerometry, used as the gold standard measurement for quantifying tremor amplitude 12,15 .…”
Section: Discussionmentioning
confidence: 99%
“…One recent study on temporal fluctuations in ET over six hours has demonstrated a good correlation of a quantitative motor assessment system with TETRAS for upper limb tremor, a subset of the TETRAS Performancescale 4 . Another study showed substantial changes of scores using the same subset after deep brain stimulation (DBS) in five patients 5 . Sensitivity to change after pharmacological intervention, either on the hand subset or of the whole TETRAS Performance scale, has not been reported to date.…”
Section: Introductionmentioning
confidence: 99%
“…Surgery was performed according to established DBS procedures described previously [13]. Briefly, we used surgical planning software (Leksell SurgiPlan, version 10.1.1; Elekta AB, Stockholm, Sweden) and a 1.5-T MRI system (Achieva 2.6.3.1; Philips, Best, The Netherlands) to target the Vim nucleus under the guidance of a stereotactic frame (Leksell Coordinate Frame G; Elekta AB).…”
Section: Methodsmentioning
confidence: 99%